The OptoGait Motion Analysis System for Clinical Assessment of 2D Spatio-Temporal Gait Parameters in Young Adults: A Reliability and Repeatability Observational Study

dc.contributor.authorCarbajales López, Julia
dc.contributor.authorBecerro de Bengoa Vallejo, Ricardo
dc.contributor.authorLosa Iglesias, Marta Elena
dc.contributor.authorCasado Hernández, Israel
dc.contributor.authorBenito de Pedro, María
dc.contributor.authorRodríguez Sanz, David
dc.contributor.authorCalvo Lobo, César 
dc.contributor.authorSan Antolín Gil, Marta
dc.date.accessioned2022-04-28T18:11:29Z
dc.date.available2022-04-28T18:11:29Z
dc.date.issued2020
dc.description.abstractBackground: Walking clinical assessments are commonly used to check for possible gait modifications in healthy subjects, in patients with trauma or neurological conditions, or after a surgical procedure. Spatio-temporal walking variables are studied in depth to achieve a complete evaluation. The purpose of this study was to perform an observational study of the reliability and repeatability of the OptoGait portable photoelectric cell system. Methods: An observational study of the reliability and repeatability of the OptoGait portable photoelectric cell system was carried out. Results: Walking point, walking point gap, step width, and walking base variables, which are deeply related to gait and posture, have an almost perfect reliability. Conclusion: The OptoGait motion analysis device is a reliable system for clinical assessment of static and dynamic foot pressures. Clinicians should feel confident adding this analysis system to their daily professional tools where repeatable measures of gait measurements are important for diagnosis and treatment selection, and also compare efficacy or testing differences between different pathologic conditions. Further, these obtained data can be formed as a baseline for future studies, and to check a right sample size for new research that use the OptoGait motion analysis system.spa
dc.description.filiationUEMspa
dc.description.impact2.679 JCR (2020) Q2, 38/90 Engineering, Multidisciplinaryspa
dc.description.impact0.435 SJR (2020) Q2, 366/2196 Computer Science Applicationsspa
dc.description.impactNo data IDR 2020spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationCarbajales-López, J., Becerro-de-Bengoa-Vallejo, R., Losa-Iglesias, M. E., Casado-Hernández, I., Benito-de Pedro, M., Rodríguez-Sanz, D., Calvo-Lobo, C., & San Antolín, M. (2020). The OptoGait Motion Analysis System for Clinical Assessment of 2D Spatio-Temporal Gait Parameters in Young Adults: A Reliability and Repeatability Observational Study. Applied Sciences, 10(11), 3726. https://doi.org/10.3390/APP10113726spa
dc.identifier.doi10.3390/APP10113726
dc.identifier.issn2076-3417
dc.identifier.urihttp://hdl.handle.net/11268/11164
dc.language.isoengspa
dc.peerreviewedSispa
dc.rightsAttribution 4.0 International (CC BY 4.0)*
dc.rights.accessRightsopen accessspa
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.otherTraumatologíaspa
dc.subject.unescoCirugíaspa
dc.subject.unescoInvestigación médicaspa
dc.titleThe OptoGait Motion Analysis System for Clinical Assessment of 2D Spatio-Temporal Gait Parameters in Young Adults: A Reliability and Repeatability Observational Studyspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublication43641780-6ebb-488f-8857-532d1133ace6
relation.isAuthorOfPublication224f44e5-15ae-48f2-8e32-ac0879c24e79
relation.isAuthorOfPublication7a5a68c1-7742-4683-8227-0ad3bc1e24db
relation.isAuthorOfPublication.latestForDiscovery43641780-6ebb-488f-8857-532d1133ace6

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
San_applsci_2020.pdf
Size:
232.2 KB
Format:
Adobe Portable Document Format
Description:
Versión del editor