Atomic force microscopy comparative analysis of the surface roughness of two posterior chamber phakic intraocular lens models: ICL versus IPCL

dc.contributor.authorGros Otero, Juan
dc.contributor.authorKetabi, Samira
dc.contributor.authorCañones Zafra, Rafael
dc.contributor.authorGarcía González, Rafael
dc.contributor.authorVilla Collar, César
dc.contributor.authorCasado, Santiago
dc.contributor.authorTeus Guezala, Miguel A.
dc.date.accessioned2023-06-18T09:53:32Z
dc.date.available2023-06-18T09:53:32Z
dc.date.issued2021
dc.description.abstractBackground To compare the anterior surface roughness of two commercially available posterior chamber phakic intraocular lenses (IOLs) using atomic force microscopy (AFM). Methods Four phakic IOLs were used for this prospective, experimental study: two Visian ICL EVO+ V5 lenses and two iPCL 2.0 lenses. All of them were brand new, were not previously implanted in humans, were monofocal and had a dioptric power of − 12 diopters (D). The anterior surface roughness was assessed using a JPK NanoWizard II® atomic force microscope in contact mode immersed in liquid. Olympus OMCL-RC800PSA commercial silicon nitride cantilever tips were used. Anterior surface roughness measurements were made in 7 areas of 10 × 10 μm at 512 × 512 point resolution. The roughness was measured using the root-mean-square (RMS) value within the given regions. Results The mean of all anterior surface roughness measurements was 6.09 ± 1.33 nm (nm) in the Visian ICL EVO+ V5 and 3.49 ± 0.41 nm in the iPCL 2.0 (p = 0.001). Conclusion In the current study, we found a statistically significant smoother anterior surface in the iPCL 2.0 phakic intraocular lenses compared with the VISIAN ICL EVO+ V5 lenses when studied with atomic force microscopy.spa
dc.description.filiationUEMspa
dc.description.impact2.086 Q3 JCR 2021spa
dc.description.impact0.788 Q2 SJR 2021spa
dc.description.impactNo data IDR 2021spa
dc.description.sponsorshipCare Groupspa
dc.identifier.citationGros-Otero, J., Ketabi, S., Cañones-Zafra, R., García-González, M., Villa-Collar, C., Casado, S., & Teus, M. A. (2021). Atomic force microscopy comparative analysis of the surface roughness of two posterior chamber phakic intraocular lens models: ICL versus IPCL. BMC Ophthalmology, 21(1), 1-9. https://doi.org/10.1186/s12886-021-02039-6spa
dc.identifier.doi10.1186/s12886-021-02039-6
dc.identifier.issn1471-2415
dc.identifier.urihttp://hdl.handle.net/11268/12144
dc.language.isoengspa
dc.peerreviewedSispa
dc.relation.publisherversionhttps://doi.org/10.1186/s12886-021-02039-6spa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopen accessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subject.otherImplantación de lentes intraocularesspa
dc.subject.otherMicroscopía de fuerza atómicaspa
dc.subject.unescoOftalmologíaspa
dc.titleAtomic force microscopy comparative analysis of the surface roughness of two posterior chamber phakic intraocular lens models: ICL versus IPCLspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublicatione19cbc49-41e7-4085-8afe-3e6d6a1608eb
relation.isAuthorOfPublication.latestForDiscoverye19cbc49-41e7-4085-8afe-3e6d6a1608eb

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Gros_Otero_2021.pdf
Size:
6.53 MB
Format:
Adobe Portable Document Format
Description:
Versión del editor