Interim restoration using dynamic abutments to re-treat a single-implant crown with a labial angulation: A clinical report
Loading...
Identifiers
Publication date
Authors
Gómez Polo, Miguel
Gómez Polo, Cristina
Celemín Viñuela, Alicia
Ortega Sánchez, Rocío
Advisors
Editors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
The cause of some peri-implant problems may be primarily attributable to the design of the prosthesis. A screw-retained interim implant may be advisable for reversibility and to avoid peri-implant cement, although screw retention may be difficult for maxillary anterior implants with a labial angulation. In the treatment described, a interim screw-retained crown was attached to a dynamic abutment with a lingual screw access hole to obtain a correctly fitting restoration.
Description
UNESCO Subjects
Keywords
Bibliographic reference
Gómez-Polo, M., Gómez-Polo, C., Celemín, A., & Ortega, R. (2018). Interim restoration using dynamic abutments to re-treat a single-implant crown with a labial angulation: A clinical report. The Journal of Prosthetic Dentistry, 120(6), 791–795. https://doi.org/10.1016/j.prosdent.2018.01.010