Interim restoration using dynamic abutments to re-treat a single-implant crown with a labial angulation: A clinical report

Loading...
Thumbnail Image
Identifiers

Publication date

Authors

Gómez Polo, Miguel
Gómez Polo, Cristina
Celemín Viñuela, Alicia
Ortega Sánchez, Rocío

Advisors

Editors

Journal Title

Journal ISSN

Volume Title

Publisher

Metrics

Google Scholar

Research Projects

Organizational Units

Journal Issue

Abstract

The cause of some peri-implant problems may be primarily attributable to the design of the prosthesis. A screw-retained interim implant may be advisable for reversibility and to avoid peri-implant cement, although screw retention may be difficult for maxillary anterior implants with a labial angulation. In the treatment described, a interim screw-retained crown was attached to a dynamic abutment with a lingual screw access hole to obtain a correctly fitting restoration.

Description

Keywords

Bibliographic reference

Gómez-Polo, M., Gómez-Polo, C., Celemín, A., & Ortega, R. (2018). Interim restoration using dynamic abutments to re-treat a single-implant crown with a labial angulation: A clinical report. The Journal of Prosthetic Dentistry, 120(6), 791–795. https://doi.org/10.1016/j.prosdent.2018.01.010

Type of document