Design of a Functional Splint for Rehabilitation of Achilles Tendon Injury Using Advanced Manufacturing (AM) Techniques. Implementation Study

dc.contributor.authorBlaya Haro, Fernando
dc.contributor.authorSan Pedro Orozco, Pilar
dc.contributor.authorBlaya San Pedro, Alonso
dc.contributor.authorLópez Silva, Julia
dc.contributor.authorJuanes Méndez, Juan A.
dc.contributor.authorD'Amato, Roberto
dc.date.accessioned2019-07-08T06:57:34Z
dc.date.available2019-07-08T06:57:34Z
dc.date.issued2019
dc.description.abstractThe use of conventional immobilization splints can cause a lot of mishaps and discomfort in patients. In addition, it is common the generation of muscle, joint and vascular complications arising from the application of classic restraint devices in this phase of treatment. Currently, it is being observed that these problems could be solved with the use of Advanced Manufacturing techniques based on Additive Manufacturing (AM), industrial digitalization and reverse engineering for the realization of individualized immobilization splints. The present study proposes to give these splints a functional character in their design adapting them to a specific pathology, in this case to the partial rupture of Achilles tendon. It also provides a comparison against the use of conventional plaster splints as an improvement factor for their definitive implementation considering the initial sanitary use for which they were designed. In this way, there have been created therapeutic windows that allow the application of rehabilitation techniques, being the treatment that would be carried out developed in parallel. The designed splint has been made in FilaFlex and Polycarbonate, materials that guarantee comfort and resistance at the same time. In addition, an optimization in terms of material has been executed, lightening the splint and reducing environmental impact and manufacturing costs. As a result of this preliminary study, a prototype on scale printed in PLA has been generated.spa
dc.description.filiationUEMspa
dc.description.impact3.058 JCR (2019) Q1, 23/102 Health Care Sciences & Services; Q2, 10/27 Medical Informaticsspa
dc.description.impact0.686 SJR (2019) Q2, 101/683 Information Systems, 12/51 Health Information Management, 28/141 Health Informatics, 932/2754 Medicine (miscellaneous)spa
dc.description.impactNo data IDR 2019spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationBlaya, F., San Pedro, P., Blaya, A., Lopez, J., Juanes, J. A., & D’Amato, R. (2019). Design of a Functional Splint for Rehabilitation of Achilles Tendon Injury Using Advanced Manufacturing (AM) Techniques. Implementation Study. Journal of Medical Systems, 43(5), 122. https://doi.org/10.1007/s10916-019-1247-zspa
dc.identifier.doi10.1007/s10916-019-1247-z
dc.identifier.issn0148-5598
dc.identifier.issn1573-689X
dc.identifier.urihttp://hdl.handle.net/11268/8086
dc.language.isoengspa
dc.peerreviewedSispa
dc.relation.publisherversionhttp://ezproxy.universidadeuropea.es/login?url=http://dx.doi.org/ 10.1007/s10916-019-1247-zspa
dc.rights.accessRightsrestricted accessspa
dc.subject.uemRehabilitaciónspa
dc.subject.uemTendonesspa
dc.subject.uemTecnología médicaspa
dc.subject.unescoRehabilitación médicaspa
dc.subject.unescoTecnología médicaspa
dc.titleDesign of a Functional Splint for Rehabilitation of Achilles Tendon Injury Using Advanced Manufacturing (AM) Techniques. Implementation Studyspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublication2cdba36d-6d1c-4acf-8d6c-9b815b5775b9
relation.isAuthorOfPublication.latestForDiscovery2cdba36d-6d1c-4acf-8d6c-9b815b5775b9

Files