Effects of Novel Inverted Rocker Orthoses for First Metatarsophalangeal Joint on Gastrocnemius Muscle Electromyographic Activity during Running: A Cross-Sectional Pilot Study

dc.contributor.authorSánchez Gómez, Rubén
dc.contributor.authorRomero Morales, Carlos
dc.contributor.authorGómez Carrión, Álvaro
dc.contributor.authorCruz Torres, Blanca de la
dc.contributor.authorZaragoza García, Ignacio
dc.contributor.authorAnttila, Pekka
dc.contributor.authorKantola, Matti
dc.contributor.authorOrtuño Soriano, Ismael
dc.date.accessioned2020-10-27T19:30:31Z
dc.date.available2020-10-27T19:30:31Z
dc.date.issued2020
dc.description.abstractBackground: The mobility of the first metatarsophalangeal joint (I MPTJ) has been related to the proper windlass mechanism and the triceps surae during the heel-off phase of running gait; the orthopedic treatment of the I MPTJ restriction has been made with typical Morton extension orthoses (TMEO). Nowadays it is unclear what effects TMEO or the novel inverted rocker orthoses (NIRO) have on the EMG activity of triceps surae during running. Objective: To compare the TMEO effects versus NIRO on EMG triceps surae on medialis and lateralis gastrocnemius activity during running. Study design: A cross-sectional pilot study. Methods: 21 healthy, recreational runners were enrolled in the present research (mean age 31.41 ± 4.33) to run on a treadmill at 9 km/h using aleatory NIRO of 6 mm, NIRO of 8 mm, TMEO of 6 mm, TMEO of 8 mm, and sports shoes only (SO), while the muscular EMG of medial and lateral gastrocnemius activity during 30 s was recorded. Statistical intraclass correlation coefficient (ICC) to test reliability was calculated and the Wilcoxon test of all five different situations were tested. Results: The reliability of values was almost perfect. Data showed that the gastrocnemius lateralis increased its EMG activity between SO vs. NIRO-8 mm (22.27 ± 2.51 vs. 25.96 ± 4.68 mV, p < 0.05) and SO vs. TMEO-6mm (22.27 ± 2.51 vs. 24.72 ± 5.08 mV, p < 0.05). Regarding gastrocnemius medialis, values showed an EMG notable increase in activity between SO vs. NIRO-6mm (22.93 ± 2.1 vs. 26.44 ± 3.63, p < 0.001), vs. NIRO-8mm (28.89 ± 3.6, p < 0.001), and vs. TMEO-6mm (25.12 ± 3.51, p < 0.05). Conclusions: Both TMEO and NIRO have shown an increased EMG of the lateralis and medialis gastrocnemius muscles activity during a full running cycle gait. Clinicians should take into account the present evidence when they want to treat I MTPJ restriction with orthoses, and consider the inherent triceps surae muscular cost relative to running economy.spa
dc.description.filiationUEMspa
dc.description.impact3.576 JCR (2020) Q1, 14/64 Instruments & Instrumentationspa
dc.description.impact0.636 SJR (2020) Q2, 46/121 Analytical Chemistryspa
dc.description.impactNo data IDR 2019spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationSánchez-Gómez, R., Romero-Morales, C., Gómez-Carrión, Á., Cruz-Torres, B. de la, Zaragoza-García, I., Anttila, P., Kantola, M., & Ortuño-Soriano, I. (2020). Effects of Novel Inverted Rocker Orthoses for First Metatarsophalangeal Joint on Gastrocnemius Muscle Electromyographic Activity during Running: A Cross-Sectional Pilot Study. Sensors, 20(11), 3205. https://doi.org/10.3390/s20113205spa
dc.identifier.doi10.3390/s20113205
dc.identifier.issn1424-3210
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/11268/9211
dc.language.isoengspa
dc.peerreviewedSispa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional
dc.rights.accessRightsopen accessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.uemAtletismospa
dc.subject.uemAparatos ortopédicosspa
dc.subject.uemDiagnóstico por imagenspa
dc.subject.unescoAtletaspa
dc.subject.unescoTecnología médicaspa
dc.subject.unescoTratamiento médicospa
dc.titleEffects of Novel Inverted Rocker Orthoses for First Metatarsophalangeal Joint on Gastrocnemius Muscle Electromyographic Activity during Running: A Cross-Sectional Pilot Studyspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublicationabb888c1-8c36-42a5-9043-43e51ba331a5
relation.isAuthorOfPublicationf7e55b2b-699c-4e9e-b57a-d4faaee07ffe
relation.isAuthorOfPublication.latestForDiscoveryabb888c1-8c36-42a5-9043-43e51ba331a5

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Romero_Morales_Sensors_2020.pdf
Size:
1.09 MB
Format:
Adobe Portable Document Format
Description:
Versión del editor