In Vivo Complete-Arch Implant Digital Impressions: Comparison of the Precision of Three Optical Impression Systems

dc.contributor.authorOrejas Pérez, Jaime
dc.contributor.authorGiménez González, Beatriz
dc.contributor.authorOrtiz Collado, Ignacio
dc.contributor.authorThuissard Vasallo, Israel John
dc.contributor.authorSantamaría Laorden, Andrés
dc.date.accessioned2023-06-05T17:39:57Z
dc.date.available2023-06-05T17:39:57Z
dc.date.issued2022
dc.description.abstractMultiple in vitro studies reported insufficient accuracy of intraoral scanners (IOSs) for complete-arch multiple implant impression. The aim of the study is to analyze the precision of three IOSs, PIC dental (Pic dental, Iditec North West SL), TRIOS 3 (3Shape), and True Definition (Midmark Corporation) and the influence of several factors in the edentulous complete maxillary and mandibular arch. A fully edentulous patient with eight implants in the maxillary and in the mandibular jaw was selected. Five impressions were taken per system and arch. A suprastructure was designed on each digital working cast. The precision was analyzed comparing each of the 28 distances and seven relative angulations of the abutments of all the designed suprastructures. The descriptive statistics, the Student’s t-test, and the ANOVA test were used to analyze the data (α = 0.05). Significant differences were observed when comparing the IOSs in some of the distances and angulations. (4) The increase in the distance between implants affected the precision of T and TD but not the PIC system. The type of arch did not affect the PIC precision, but the T and TD systems performed worse in the mandibular arch. The system with the best precision was the PIC, followed by TD, and then T.spa
dc.description.filiationUEMspa
dc.description.impactNo data JCR 2022spa
dc.description.impact0.828 Q2 SJR 2022spa
dc.description.impactNo data IDR 2022spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationOrejas-Pérez, J., Giménez-González, B., Ortiz-Collado, I., Thuissard, I. J., & Santamaría-Laorden, A. (2022). In Vivo Complete-Arch Implant Digital Impressions: Comparison of the Precision of Three Optical Impression Systems. International Journal of Environmental Research and Public Health, 19(7), 4300. https://doi.org/10.3390/ijerph19074300spa
dc.identifier.doi10.3390/ijerph19074300
dc.identifier.issn1660-4601
dc.identifier.urihttp://hdl.handle.net/11268/12110
dc.language.isoengspa
dc.peerreviewedSispa
dc.relation.publisherversionhttps://doi.org/10.3390/ijerph19074300spa
dc.rightsAttribution 4.0 International (CC BY 4.0)spa
dc.rights.accessRightsopen accessspa
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/spa
dc.subject.otherImplantación dentalspa
dc.subject.otherImpresión tridimensionalspa
dc.subject.otherMateriales biocompatiblesspa
dc.subject.unescoOdontologíaspa
dc.subject.unescoTecnología médicaspa
dc.titleIn Vivo Complete-Arch Implant Digital Impressions: Comparison of the Precision of Three Optical Impression Systemsspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublication74d2eb56-d778-47c3-b338-76cd3d9e5f3c
relation.isAuthorOfPublication6ec266f2-8e29-4c5c-be70-5f0a58f67db8
relation.isAuthorOfPublication.latestForDiscovery74d2eb56-d778-47c3-b338-76cd3d9e5f3c

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Orejas_Ortiz_Thuissard_IJERPH_2022.pdf
Size:
3.64 MB
Format:
Adobe Portable Document Format
Description:
Versión del editor