Influence of Commonly Used Endodontic Irrigants on the Setting Time and Metal Composition of Various Base Endodontic Sealers

dc.contributor.authorJose, Jerry
dc.contributor.authorVenkata Teja, Kavalipurapu
dc.contributor.authorRanjan, Manish
dc.contributor.authorNoor Mohamed, Roshan
dc.contributor.authorKhursheed Alam, Mohammad
dc.contributor.authorShrivastava, Deepti
dc.contributor.authorNatoli, Valentino
dc.contributor.authorKumar Nagarajappa, Anil
dc.contributor.authorJanani, Krishnamachari
dc.contributor.authorChandan Srivastava, Kumar
dc.date.accessioned2022-04-19T14:56:38Z
dc.date.available2022-04-19T14:56:38Z
dc.date.issued2022
dc.description.abstractThe present study aimed to evaluate if commonly used endodontic irrigants such as 3% sodium hypochlorite (NaOCl, Prime Dental, Thane, India), 2% chlorhexidine (CHX, Sigma-Aldrich Co., St. Louis, MO, USA), and 17% ethylenediaminetetraacetic acid (EDTA, Meta-Biomed Co. Ltd., Cheongju-si, South Korea) influenced the setting time and metal composition of different base endodontic sealers on exposure. AH Plus (Dentsply De Trey GmbH, Konstanz, Germany), Sealapex (SybronEndo, Orange, CA, USA), mineral trioxide aggregate (MTA) Fillapex (Angelus Soluções Odontológicas, Londrina, Brazil), and Tubli-Seal (Kerr Dental, Orange, CA, USA) were selected as the different base representatives of endodontic sealers. These sealers were exposed to 3% NaOCl, 2% CHX, and 17% EDTA, and the individual setting time of the sealers was analyzed. The samples were analyzed for heavy metal elements such as chromium (Cr), nickel (Ni), cobalt (Co), cadmium (Cd), arsenic (As), mercury (Hg), lead (Pb), and beryllium (Be) by using inductively coupled plasma mass spectrometry (ICP-MS) analysis. For statistical analysis, one-way ANOVA and post hoc Tukey's tests were used. All selected sealers showed variation in setting time post-exposure to different irrigants. MTA Fillapex had the shortest mean setting time (215.7 min, post-exposure at 187.3 min) (p < 0.05). Mean setting time was also affected for AH Plus (479.6 min, post-exposure at 423.9 min) (p < 0.05) and Tubli-Seal (514.7 min, post-exposure at 465.2 min) (p < 0.05). Sealapex showed the maximum reduction of setting time (864.8 min, post-exposure at 673.4 min) (p < 0.05). All tested sealers showed heavy metals (Cr, Ni, Co, Cd, As, Hg, and Pb) in their composition, and the quantities were influenced by interaction with different irrigants. The heavy metal Be was not seen in any of the samples. Sealapex showed the longest setting time in comparison to other test sealers. Heavy metals were most present in Sealapex, followed by AH Plus, Tubli-Seal, and MTA Fillapex. MTA Fillapex was seen to have the shortest setting time, and heavy metal composition was least affected on interaction with different commonly used endodontic irrigants. Further, this study provides significant insight into the influence of different endodontic irrigants on interaction with different base endodontic sealers, which has not been reported previously, and future studies should emphasize endodontic irrigant-sealer interactions and their possible effects in the long run.spa
dc.description.filiationUEMspa
dc.description.impact4.967 Q1 JCR 2021spa
dc.description.impact0.726 Q1 SJR 2021spa
dc.description.impactNo data IDR 2021spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationJose, J., Teja, K. V., Ranjan, M., Mohamed, R. N., Alam, M. K., Shrivastava, D., Natoli, V., Nagarajappa, A. K., Janani, K., & Srivastava, K. C. (2021). Influence of Commonly Used Endodontic Irrigants on the Setting Time and Metal Composition of Various Base Endodontic Sealers. Polymers, 14(1), 27. https://doi.org/10.3390/polym14010027spa
dc.identifier.doi10.3390/polym14010027
dc.identifier.issn2073-4360
dc.identifier.urihttp://hdl.handle.net/11268/11066
dc.language.isoengspa
dc.peerreviewedSispa
dc.rightsAtribución 4.0 Internacional*
dc.rights.accessRightsopen accessspa
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subject.otherImplantación dentalspa
dc.subject.otherMateriales dentalesspa
dc.subject.unescoOdontologíaspa
dc.subject.unescoTecnología médicaspa
dc.titleInfluence of Commonly Used Endodontic Irrigants on the Setting Time and Metal Composition of Various Base Endodontic Sealersspa
dc.typejournal articlespa
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Natoli_Polymers_2022.pdf
Size:
936.94 KB
Format:
Adobe Portable Document Format
Description:
Versión del editor