Comparison of the accuracy of 11 intraocular lens power calculation formulas

dc.contributor.authorCarmona González, David
dc.contributor.authorCastillo Gómez, Alfredo
dc.contributor.authorPalomino Bautista, Carlos
dc.contributor.authorRomero Domínguez, Marta
dc.contributor.authorGutiérrez Moreno, María Ángeles
dc.date.accessioned2022-01-21T18:48:18Z
dc.date.available2022-01-21T18:48:18Z
dc.date.issued2020
dc.description.abstractPurpose: To compare the accuracy of 11 intraocular lens (IOL) power calculation formulas (SRK-T, Hoffer Q, Holladay I, Haigis, Holladay II, Olsen, Barrett Universal II, Hill-RBF, Ladas Super formula, EVO and Kane). Setting: Private university hospital (QuironSalud, Madrid, Spain). Design: Retrospective case series. Methods: Data were compiled from 481 eyes of 481 patients who had undergone uneventful cataract surgery with IOL insertion. Preoperative biometric measurements were made using an IOL Master® 700. Respective ULIB IOL constants (http://ocusoft.de/ulib/c1.htm) for each of 4 IOL models implanted were used to calculate the predictive refractive outcome for each formula. This was compared with the actual refractive outcome determined 3 months postoperatively. The primary outcome was mean absolute prediction error (MAE). The study sample was divided according to axial length (AL) into three groups of eyes: short (⩽22.00 mm), normal (22.00-25.00 mm) and long (⩾25.00 mm). Results: The Barrett Universal II and Haigis formulas yielded the lowest MAEs over the entire AL range (p < .01, except EVO) as well as in the long (p < .01, all formulas) and normal (p < .01, except Haigis, Holladay II, Olsen and LSF) eyes. In the short eyes, the lower MAEs were provided by Haigis and EVO (p < .01 except Hoffer Q, SRK/T and Holladay I). Conclusions: Barrett Universal II was the most accurate for IOL power calculation in the normal and long eyes. For short eyes, the formulas Haigis and EVO seem best at predicting refractive outcomes.spa
dc.description.filiationUEMspa
dc.description.impact2.597 JCR (2020) Q3, 33/62 Ophthalmologyspa
dc.description.impact0.790 SJR (2020) Q2, 43/124 Ophthalmologyspa
dc.description.impactNo IDR 2020spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationCarmona-González, D., Castillo-Gómez, A., Palomino-Bautista, C., Romero-Domínguez, M., & Gutiérrez-Moreno, M. Á. (2021). Comparison of the accuracy of 11 intraocular lens power calculation formulas. European Journal of Ophthalmology, 31(5), 2370-2376. https://doi.org/10.1177/1120672120962030spa
dc.identifier.doi10.1177/1120672120962030
dc.identifier.issn1120-6721
dc.identifier.issn1724-6016
dc.identifier.urihttp://hdl.handle.net/11268/10611
dc.language.isoengspa
dc.peerreviewedSispa
dc.rights.accessRightsrestricted accessspa
dc.subject.otherTerapia por láserspa
dc.subject.otherLongitud axial del ojospa
dc.subject.otherCristalinospa
dc.subject.unescoOftalmologíaspa
dc.subject.unescoTecnología médicaspa
dc.subject.unescoBiometríaspa
dc.titleComparison of the accuracy of 11 intraocular lens power calculation formulasspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublication3fb16c7a-d1be-46b4-97b1-d4d969dd8a8a
relation.isAuthorOfPublication72c88ebd-110e-4cd5-a00a-386334318d44
relation.isAuthorOfPublication.latestForDiscovery3fb16c7a-d1be-46b4-97b1-d4d969dd8a8a

Files