Evaluation of Cardiac Shunts With 4D Flow Cardiac Magnetic Resonance: Intra- and Interobserver Variability
| dc.contributor.author | Urmeneta Ulloa, Javier | |
| dc.contributor.author | Álvarez Vázquez, Ana Isabel | |
| dc.contributor.author | Martínez de Vega, Vicente | |
| dc.contributor.author | Cabrera Rodríguez, José Ángel | |
| dc.date.accessioned | 2022-01-28T18:40:45Z | |
| dc.date.available | 2022-01-28T18:40:45Z | |
| dc.date.issued | 2020 | |
| dc.description.abstract | Background: In the last decade, the capacity of magnetic resonance (MR) to evaluate congenital anomalies has improved substantially. To date, only a few studies have evaluated the value of 4D-flow MRI in shunt assessments. Purpose/hypothesis: To assess the intra- and interobserver variability of 4D-flow MRI in patients diagnosed with cardiac/extracardiac shunt. Secondarily, to assess the feasibility of directly measuring the shunt and to determine the prognostic correlation with the pulmonary-to-systemic (Qp/Qs) flow ratio. Study type: Retrospective. Population: In all, 18 patients with cardiac shunt diagnosis. Field strength/sequence: 1.5 T/4D phase-contrast MRI. Assessment: Pulmonary and systemic flows were measured at different locations to assess the internal consistency by two observers (twice by one, and once by the other). The Qp/Qs ratio was calculated. When feasible, direct flow was quantified by planimetry. Statistical tests: Spearman's rho correlation coefficient was used to assess the relationship between pulmonary/systemic flows measured at different levels and to compare the jet characteristics with prognostic data as right ventricle volume. Intra- and interobserver variability were determined by Bland-Altman plots and interobserver correlation. Results: The most common shunt type (n = 10; 55.5%) was ostium secundum atrial septal defect (ASD). Direct visualization and quantification of shunt flow was possible in all studies. Pulmonary and systemic flows showed a strong correlation between these measures (Spearman's rho [r] of 0.872 and 0.899). The mean Qp/Qs ratio was 1.61(0.62). Mean flow rate was 2.01(1.68) l/min. The mean jet diameter was 11.88 (5.44) mm. Intraobserver (r = 0.97) and interobserver correlation (ICC = 0.95) for the Qp/Qs calculation were both excellent. Direct measurement of flow was strongly correlated (r = 0.98; ICC = 0.95). Correlation was strong between Qp/Qs and direct jet flow (r = 0.76 and 0.77), Qp/Qs and mean jet diameter (r = 0.79 and 0.94), and Qp/Qs with jet area (r = 0.77 and 0.94). Data conclusion: Measurement of the Qp/Qs ratio and direct shunt quantification using 4D-flow MRI was feasible, and highly reproducible. Internal consistency was excellent, with low intra- and interobserver variability. Correlation between the Qp/Qs ratio, direct flow measurement, mean diameter, and jet area was strong. Evidence level: 3 TECHNICAL EFFICACY: Stage 2 J. Magn. Reson. Imaging 2020;52:1055-1063. | spa |
| dc.description.filiation | UEM | spa |
| dc.description.impact | 4.813 JCR (2020) Q2, 26/133 Radiology, Nuclear Medicine & Medical Imaging | spa |
| dc.description.impact | 1.563 SJR (2020) Q1, 29/338 Radiology, Nuclear Medicine and Imaging | spa |
| dc.description.impact | No data IDR 2020 | spa |
| dc.description.sponsorship | Sin financiación | spa |
| dc.identifier.citation | Urmeneta Ulloa, J., Álvarez Vázquez, A., Martínez de Vega, V., & Cabrera, J. Á. (2020). Evaluation of Cardiac Shunts With 4D Flow Cardiac Magnetic Resonance: Intra‐ and Interobserver Variability. Journal of Magnetic Resonance Imaging, 52(4), 1055-1063. https://doi.org/10.1002/jmri.27158 | spa |
| dc.identifier.doi | 10.1002/jmri.27158 | |
| dc.identifier.issn | 1053-1807 | |
| dc.identifier.issn | 1522-2586 | |
| dc.identifier.uri | http://hdl.handle.net/11268/10664 | |
| dc.language.iso | eng | spa |
| dc.peerreviewed | Si | spa |
| dc.rights.accessRights | restricted access | spa |
| dc.subject.other | Imagen por resonancia magnética | spa |
| dc.subject.other | Cardiopatías | spa |
| dc.subject.unesco | Enfermedad cardiovascular | spa |
| dc.subject.unesco | Tecnología médica | spa |
| dc.subject.unesco | Medicina preventiva | spa |
| dc.title | Evaluation of Cardiac Shunts With 4D Flow Cardiac Magnetic Resonance: Intra- and Interobserver Variability | spa |
| dc.type | journal article | spa |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 744ef0de-0c66-4902-9653-6aa4802312c3 | |
| relation.isAuthorOfPublication | c151d669-9818-47b4-b683-19457fc8e162 | |
| relation.isAuthorOfPublication | a39ba113-54a7-4611-8ba4-03c7bbd51a03 | |
| relation.isAuthorOfPublication.latestForDiscovery | 744ef0de-0c66-4902-9653-6aa4802312c3 |

