Frequency of technical complications in fixed implant prosthesis: the effect of prosthesis screw emergence correction by CAD-CAM

dc.contributor.authorAnitua, Eduardo
dc.contributor.authorFlores, Carlos
dc.contributor.authorPiñas Caballero, Laura
dc.contributor.authorAlkhraisat, Mohammad Hamdan
dc.date.accessioned2018-10-29T17:20:50Z
dc.date.available2018-10-29T17:20:50Z
dc.date.issued2018
dc.description.abstractCAD-CAM technology permits the angular correction of screw emergence into the prosthesis, however there is lack of controlled clinical studies that assess the frequency of technical complications in angled screw channel restorations. This controlled clinical study was designed to assess technical incidences in angled screw channel restorations. Patients having implant prosthesis placed between November, 2014 and December, 2015 were screened. The patients were selected if they received prosthesis with up to 30º correction of the prosthesis screw emergence and had at least one non-angulated prosthesis (screw-retained). All the prostheses were located completely/partially in the posterior region. The frequency of technical complications was the principal variable. A total of 52 patients with a mean age of 62 ± 10 years participated with a total 110 prostheses (55 in the test group and 55 in the control group). A total of 11 technical complications occurred (7 in the test group and 4 in the control group). These differences were not statistically significant. All the prostheses in both groups survived the follow-up. The correction of the screw emergence into the prosthesis has not increased the risk of technical complications in CAD-CAM implant prostheses.spa
dc.description.filiationUEMspa
dc.description.impact1.062 JCR (2018) Q4, 76/91 Dentistry, Oral Surgery & Medicinespa
dc.description.impact0.573 SJR (2018) Q3, 25/50 Oral Surgeryspa
dc.description.impactNo data IDR 2018spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationAnitua, E., Flores, C., Piñas Caballero, L., & Alkhraisat, M. H. (2018). Frequency of technical complications in fixed implant prosthesis: the effect of prosthesis screw emergence correction by CAD-CAM. Journal of Oral Implantology, 44(6), 427-431. https://doi.org/10.1563/aaid-joi-D-17-00229spa
dc.identifier.doi10.1563/aaid-joi-D-17-00229
dc.identifier.issn0160-6972
dc.identifier.issn1548-1336
dc.identifier.urihttp://hdl.handle.net/11268/7526
dc.language.isoengspa
dc.peerreviewedSispa
dc.rights.accessRightsrestricted accessspa
dc.subject.uemOdontología restauradoraspa
dc.subject.uemPrótesis dentalesspa
dc.subject.uemImplantes dentalesspa
dc.subject.unescoOdontologíaspa
dc.subject.unescoTecnología médicaspa
dc.titleFrequency of technical complications in fixed implant prosthesis: the effect of prosthesis screw emergence correction by CAD-CAMspa
dc.typejournal articlespa