Real-World Comparison of Balloon-Expandable Valves for Transcatheter Aortic Valve Replacement: Data From the AorticþMitral TRAansCatheter Valve Registry
| dc.contributor.author | Talmor Barkan, Yeela | |
| dc.contributor.author | Patel, Kush P. | |
| dc.contributor.author | Barbanti, Marco | |
| dc.contributor.author | Sammartino, Sofia | |
| dc.contributor.author | Costa, Giuliano | |
| dc.contributor.author | Grasso, Carmelo | |
| dc.contributor.author | De Backer, Ole | |
| dc.contributor.author | Lulic, Davorka | |
| dc.contributor.author | Olmos Blanco, Carmen | |
| dc.contributor.author | Witberg, Guy | |
| dc.contributor.author | Et al. | |
| dc.date.accessioned | 2026-10-18T11:22:15Z | |
| dc.date.available | 2026-10-18T11:22:15Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | Background: Comparative real-world data on newer balloon-expandable valve (BEV) platforms remain limited. We sought to compare clinical, procedural, and early hemodynamic outcomes following transcatheter aortic valve replacement (TAVR) using 2 contemporary BEVs in a multicenter international registry. Methods: Consecutive patients undergoing TAVR with Sapien 3/Ultra and MyVal from the Aortic+Mitral TRAansCatheter Valve Registry were included. Propensity score matching was used to generate a balanced 1:3 cohort. The primary endpoint was 2-year all-cause mortality. Secondary endpoints included in-hospital complications, defined according to Valve Academic Research Consortium–3 criteria. | |
| dc.description.filiation | UEM | spa |
| dc.description.impact | 3.4 Q2 JCR 2025 | |
| dc.description.impact | 1.054 Q1 SJR 2025 | |
| dc.description.impact | No data IDR 2025 | |
| dc.description.sponsorship | Sin financiación | |
| dc.identifier.citation | Talmor-Barkan, Y., Patel, K. P., Barbanti, M., Sammartino, S., Costa, G., Grasso, C., De Backer, O., Lulic, D., Olmos, C., Masiero, G., Adamo, M., Arzamendi, D., García-Gómez, M., Baz, J. A., Steblovnik, K., Mauri, V., Adam, M., Wienemann, H., Hein, M., … Witberg, G. (2026). Real-world comparison of balloon-expandable valves for transcatheter aortic valve replacement: Data from the aortic+mitral traanscatheter valve registry. Structural Heart, 10(10), 101104. https://doi.org/10.1016/j.shj.2026.101104 | |
| dc.identifier.doi | 10.1016/j.shj.2026.101104 | |
| dc.identifier.issn | 2474-8706 | |
| dc.identifier.uri | https://hdl.handle.net/11268/17494 | |
| dc.language.iso | eng | |
| dc.peerreviewed | Si | |
| dc.relation.publisherversion | https://doi.org/10.1016/j.shj.2026.101104 | |
| dc.rights.accessRights | open access | |
| dc.subject.sdg | Goal 3: Ensure healthy lives and promote well-being for all at all ages | |
| dc.subject.unesco | Enfermedad cardiovascular | |
| dc.subject.unesco | Cirugía | |
| dc.subject.unesco | Tecnología médica | |
| dc.title | Real-World Comparison of Balloon-Expandable Valves for Transcatheter Aortic Valve Replacement: Data From the AorticþMitral TRAansCatheter Valve Registry | |
| dc.type | journal article | |
| dc.type.hasVersion | VoR | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 48c5a11b-6968-4977-b4a8-7ec2b5143e22 | |
| relation.isAuthorOfPublication.latestForDiscovery | 48c5a11b-6968-4977-b4a8-7ec2b5143e22 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- BalloonExpandableValves_AMTRAC_StructuralHeart_2026.pdf
- Size:
- 2.03 MB
- Format:
- Adobe Portable Document Format