Effects of Extender Type, Storage Time, and Temperature on Bull Semen Parameters

dc.contributor.authorFernández Novo, Aitor
dc.contributor.authorSantos López, Sergio
dc.contributor.authorBarrajón Masa, Clara
dc.contributor.authorMozas, Patricia
dc.contributor.authorMercado, Eduardo de
dc.contributor.authorCáceres, Elisa
dc.contributor.authorGarrafa, Aizic
dc.contributor.authorGonzález Martín, Juan Vicente
dc.contributor.authorPérez Villalobos, Natividad
dc.contributor.authorOliet, Agustín
dc.contributor.authorAstiz Blanco, Susana
dc.contributor.authorPérez Garnelo, Sonia S.
dc.date.accessioned2021-10-19T18:18:16Z
dc.date.available2021-10-19T18:18:16Z
dc.date.issued2021
dc.description.abstractSeminal parameters can be evaluated in situ, or samples can be delivered to a diagnostic centre. How storage conditions affect ejaculates up to evaluation is unclear. We assessed, in 25 commercial bulls electroejaculated in the field, the impact of time until evaluation (0–2 h, 4–6 h, and 24 h post-ejaculation), holding temperature (5 °C vs. room temperature), and extender (AndroMed®, BIOXcell® or INRA96®) on semen quality. Acrosome integrity, sperm viability and morphology, CASA-total and progressive motility, pH, and colony-forming units were assessed. Semen quality was preserved for up to 4–6 h post-ejaculation, except for INRA96® at 5 °C. Regardless of extender or temperature, motility decreased from 4 to 6 h up to 24 h, with the best values obtained with BIOXcell® at 5 °C. pH differed from 4 to 6 h up to 24 h, acidifying when stored at room temperature. Microbiological load was stable over time with AndroMed® and BIOXcell®, and increased at room temperature with INRA96®. Our results suggest that AndroMed® and BIOXcell® can preserve semen quality for up to 6 h, either at 5 °C or room temperature, while INRA96® only at room temperature. These results help to fix adequate protocols for short-term storage and shipment of bovine semen collected under field conditions.spa
dc.description.filiationUEMspa
dc.description.impact5.168 JCR (2021) Q1, 21/94 Biologyspa
dc.description.impact0.903 SJR (2021) Q1, 43/322 Agricultural and Biological Sciences (miscellaneous)spa
dc.description.impactNo data IDR 2021spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationFernández-Novo, A., Santos-López, S., Barrajón-Masa, C., Mozas, P., de Mercado, E., Cáceres, E., Garrafa, A., González-Martin, J. V., Pérez-Villalobos, N., Oliet, A., Astiz, S., & Pérez-Garnelo, S. S. (2021). Effects of extender type, storage time, and temperature on bull semen parameters. Biology, 10(7), 630. https://doi.org/10.3390/biology10070630spa
dc.identifier.doi10.3390/biology10070630
dc.identifier.issn2079-7737
dc.identifier.urihttp://hdl.handle.net/11268/10415
dc.language.isoengspa
dc.peerreviewedSispa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacionalspa
dc.rights.accessRightsopen accessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/spa
dc.subject.otherFertilizaciónspa
dc.subject.otherSemenspa
dc.subject.otherMedicina veterinariaspa
dc.subject.unescoGanado vacunospa
dc.subject.unescoFecundidadspa
dc.subject.unescoBiologíaspa
dc.titleEffects of Extender Type, Storage Time, and Temperature on Bull Semen Parametersspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublicatione2039592-96f5-444b-b956-9825ffa8f192
relation.isAuthorOfPublication9f0b1d65-4ede-4a5c-a4e8-e29ae8dd8eaa
relation.isAuthorOfPublication6a2e2d62-0379-40c6-bb61-6865ad7c5e91
relation.isAuthorOfPublication.latestForDiscoverye2039592-96f5-444b-b956-9825ffa8f192

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Novo_biology_2021.pdf
Size:
2.17 MB
Format:
Adobe Portable Document Format
Description:
Versión del editor