Influence of camera position, implant angulation and implant reference on the accuracy of complete arch implant recordings with photogrammetry

dc.contributor.authorBenabdallah M’Rabat, Meriem
dc.contributor.authorSantamaría Laorden, Andrea
dc.contributor.authorBertuol Gessi, Sabina Francesca
dc.contributor.authorMartínez Marugán, Alicia
dc.contributor.authorSuárez García, Ana
dc.contributor.authorThuissard Vasallo, Israel John
dc.contributor.authorOrejas Pérez, Jaime
dc.date.accessioned2026-01-13T17:02:14Z
dc.date.available2026-01-13T17:02:14Z
dc.date.issued2025
dc.description.abstractThe aim of the present study was to assess the influence of various implant angulations, camera positions and number of implant references on the accuracy of a photogrammetry device for complete arch implant prostheses. Implant angulations, camera positions and number of implant references used affected the precision and trueness of Precise Implant Capture (PIC) system. However, these differences did not show clinically relevant values.
dc.description.filiationUEM
dc.description.impact2.5 Q2 JCR 2024
dc.description.impact0.852 Q1 SJR 2024
dc.description.impactNo data IDR 2024
dc.description.sponsorshipSin financiación
dc.identifier.citationBenabdallah-M’Rabat, M., Santamaria-Laorden, A., Bertuol-Gessi, S. F., Martínez-Marugán, A., Suarez-García, A., Thuissard, I. J., & Orejas-Pérez, J. (2025). Influence of camera position, implant angulation and implant reference on the accuracy of complete arch implant recordings with photogrammetry. The Journal of Advanced Prosthodontics, 17(5), 292. https://doi.org/10.4047/jap.2025.17.5.292
dc.identifier.doi10.4047/jap.2025.17.5.292
dc.identifier.issn2005-7806
dc.identifier.issn2005-7814
dc.identifier.urihttps://hdl.handle.net/11268/16708
dc.language.isoeng
dc.peerreviewedSi
dc.relation.publisherversionhttps://doi.org/10.4047/jap.2025.17.5.292
dc.rightsAttribution-NonCommercial 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.subject.sdgGoal 3: Ensure healthy lives and promote well-being for all at all ages
dc.subject.sdgGoal 4: Quality education
dc.subject.sdgGoal 9: Build resilient infrastructure, promote sustainable industrialization and foster innovation
dc.subject.unescoCiencias médicas
dc.subject.unescoOdontología
dc.subject.unescoMedicina preventiva
dc.titleInfluence of camera position, implant angulation and implant reference on the accuracy of complete arch implant recordings with photogrammetry
dc.typejournal article
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublicationa1efacd5-7be0-4c41-953a-0c0326dc64ad
relation.isAuthorOfPublication5b4560dd-f76a-48c2-a526-0e7dc9183ed5
relation.isAuthorOfPublication6ec266f2-8e29-4c5c-be70-5f0a58f67db8
relation.isAuthorOfPublication74d2eb56-d778-47c3-b338-76cd3d9e5f3c
relation.isAuthorOfPublication.latestForDiscoverya1efacd5-7be0-4c41-953a-0c0326dc64ad

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Influence_of_camera_position_implant_angulation_and_implant_reference_on_the_accuracy_of_complete_arch_implant_recordings_with_photogrammetry.pdf
Size:
1.51 MB
Format:
Adobe Portable Document Format