Electromyography comparison of the effects of various footwear in the activity patterns of the peroneus longus and brevis muscles

Loading...
Thumbnail Image
Identifiers

Publication date

Authors

Roca Dols, Andrea
Losa Iglesias, Marta Elena
López López, Daniel
Becerro de Bengoa Vallejo, Ricardo

Advisors

Editors

Journal Title

Journal ISSN

Volume Title

Publisher

Metrics

Google Scholar

Research Projects

Organizational Units

Journal Issue

Abstract

Peroneus longus and brevis (PLB) disorders are commonly in people with lateral ligamentous instability, ankle pain, lateral hindfoot pain and structures of the proximal compartment of the lower legs and their muscle activity is believed to be influenced by different footwear types. The proposal of this research is to evaluate the effects of five types of footwear with respect to the barefoot condition and analyze the activity patterns of PLB muscles in healthy subjects during the gait cycle. Methods Thirty healthy subjects were recruited in a laboratory in this cross-sectional research design. While walking, electromyography (EMG) activity was measured from PLB via surface electrodes in six experimental conditions: 1) barefoot, 2) minimalist, 3) pronated control, 4) air chamber, 5) ethyl-vinyl-acetate (EVA) and 6) boost. These data were obtained and compared. Results The peroneus brevis showed significant reductions in the peak amplitude of the five footwear types (minimalist, pronation control, air chamber, EVA and boost) with respect to the barefoot condition in the propulsion phase of the gait cycle during walking (P = 0.034; P < 0.001; P < 0.001; P < 0.001; P = 0.006) and running (P = 0.004; P < 0.001; P = 0.001; P < 0.001; P = 0.001), respectively. Furthermore, peroneus longus showed significant reductions in the peak amplitude of these five footwear types with respect to the barefoot condition in the propulsion phase of the gait cycle during running (P = 0.005; P = 0.038; P = 0.019; P = 0.025; P = 0.021). Conclusion The EMG activity patterns of the PLB muscles may depend on the use of different types of sport shoes such as minimalist, pronation control, air chamber, EVA and boost footwear with respect the barefoot condition in different phases of the gait cycle during walking and running.

Description

Keywords

Bibliographic reference

Roca-Dols, A., Losa-Iglesias, M. E., Sánchez-Gómez, R., López-López, D., Becerro-de-Bengoa-Vallejo, R., & Calvo-Lobo, C. (2018). Electromyography comparison of the effects of various footwear in the activity patterns of the peroneus longus and brevis muscles. Journal of the mechanical behavior of biomedical materials, 82, 126-132. https://doi.org/10.1016/j.jmbbm.2018.03.003

Type of document