Accuracy of Cirrus HD-OCT and Topcon SP-3000P for measuring central corneal thickness

dc.contributor.authorCalvo Sanz, Jorge Antonio
dc.contributor.authorRuiz Alcocer, Javier
dc.contributor.authorSánchez Tena, Miguel Ángel
dc.date.accessioned2017-05-22T11:26:24Z
dc.date.available2017-05-22T11:26:24Z
dc.date.issued2018
dc.description.abstractThe purpose of this study is to o compare and analyze the interchangeability of three measuring systems, each based on a different technique, for central corneal thickness (CCT) analysis. Methods: CCT measurements were measured using optical coherence tomography (OCT), noncontact specular microscopy (NCSM), and ultrasonic pachymetry (USP) in 60 eyes of 60 healthy patients with a mean age of 66.5 ± 15.0 years and a mean spherical equivalent of 0.43 ± 1.14 D. Analysis of variations in measurement concordance and correlation among the three different methods were performed. Comparison of CCT measurements were done using Bland---Altman plots (with bias and 95% confidence intervals), intraclass correlation coefficient (ICC), and paired t-student analysis. OCT and UPS offered highly comparable results, whereas NCSM offered lower mean CCT values compared to the other two methods. Therefore, NCSM should not be considered a reliable method for measuring CCT and should rather be considered for assessing longitudinal changes in the same patient.spa
dc.description.filiationUEMspa
dc.description.impactNo data JCR 2018spa
dc.description.impact0.830 SJR (2018) Q1, 3/12 Optometryspa
dc.description.impactNo data IDR 2018spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationCalvo-Sanz, J. A., Ruiz-Alcocer, J., & Sánchez-Tena, M. A. (2018). Accuracy of Cirrus HD-OCT and Topcon SP-3000P for measuring central corneal thickness. Journal of Optometry, 11(3), 192-197. http://doi.org/10.1016/j.optom.2016.12.004spa
dc.identifier.doi10.1016/j.optom.2016.12.004
dc.identifier.issn19891342
dc.identifier.issn18884296
dc.identifier.urihttp://hdl.handle.net/11268/6426
dc.language.isoengspa
dc.peerreviewedSispa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.accessRightsopen accessspa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subject.uemCórnea - Enfermedadesspa
dc.subject.uemOptometríaspa
dc.subject.unescoÓpticaspa
dc.titleAccuracy of Cirrus HD-OCT and Topcon SP-3000P for measuring central corneal thicknessspa
dc.title.alternativePrecisión de Cirrus HD-OCT y Topcon SP-3000P en la medición del espesor corneal centralspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublicationd04537ee-c759-486d-9860-07ddf32301d0
relation.isAuthorOfPublication49c11cd7-8122-4e1b-a814-94ac44f3928e
relation.isAuthorOfPublication410ff67b-2bce-4f68-97d9-5dcf8d7afc54
relation.isAuthorOfPublication.latestForDiscoveryd04537ee-c759-486d-9860-07ddf32301d0

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Calvo-Sanz JA Accuracy of Cirrus HD-OCT and Topcon SP-3000P for measuring central corneal thickness.pdf
Size:
720.54 KB
Format:
Adobe Portable Document Format
Description:
Versión del editor