Accuracy of Cirrus HD-OCT and Topcon SP-3000P for measuring central corneal thickness
| dc.contributor.author | Calvo Sanz, Jorge Antonio | |
| dc.contributor.author | Ruiz Alcocer, Javier | |
| dc.contributor.author | Sánchez Tena, Miguel Ángel | |
| dc.date.accessioned | 2017-05-22T11:26:24Z | |
| dc.date.available | 2017-05-22T11:26:24Z | |
| dc.date.issued | 2018 | |
| dc.description.abstract | The purpose of this study is to o compare and analyze the interchangeability of three measuring systems, each based on a different technique, for central corneal thickness (CCT) analysis. Methods: CCT measurements were measured using optical coherence tomography (OCT), noncontact specular microscopy (NCSM), and ultrasonic pachymetry (USP) in 60 eyes of 60 healthy patients with a mean age of 66.5 ± 15.0 years and a mean spherical equivalent of 0.43 ± 1.14 D. Analysis of variations in measurement concordance and correlation among the three different methods were performed. Comparison of CCT measurements were done using Bland---Altman plots (with bias and 95% confidence intervals), intraclass correlation coefficient (ICC), and paired t-student analysis. OCT and UPS offered highly comparable results, whereas NCSM offered lower mean CCT values compared to the other two methods. Therefore, NCSM should not be considered a reliable method for measuring CCT and should rather be considered for assessing longitudinal changes in the same patient. | spa |
| dc.description.filiation | UEM | spa |
| dc.description.impact | No data JCR 2018 | spa |
| dc.description.impact | 0.830 SJR (2018) Q1, 3/12 Optometry | spa |
| dc.description.impact | No data IDR 2018 | spa |
| dc.description.sponsorship | Sin financiación | spa |
| dc.identifier.citation | Calvo-Sanz, J. A., Ruiz-Alcocer, J., & Sánchez-Tena, M. A. (2018). Accuracy of Cirrus HD-OCT and Topcon SP-3000P for measuring central corneal thickness. Journal of Optometry, 11(3), 192-197. http://doi.org/10.1016/j.optom.2016.12.004 | spa |
| dc.identifier.doi | 10.1016/j.optom.2016.12.004 | |
| dc.identifier.issn | 19891342 | |
| dc.identifier.issn | 18884296 | |
| dc.identifier.uri | http://hdl.handle.net/11268/6426 | |
| dc.language.iso | eng | spa |
| dc.peerreviewed | Si | spa |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | * |
| dc.rights.accessRights | open access | spa |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
| dc.subject.uem | Córnea - Enfermedades | spa |
| dc.subject.uem | Optometría | spa |
| dc.subject.unesco | Óptica | spa |
| dc.title | Accuracy of Cirrus HD-OCT and Topcon SP-3000P for measuring central corneal thickness | spa |
| dc.title.alternative | Precisión de Cirrus HD-OCT y Topcon SP-3000P en la medición del espesor corneal central | spa |
| dc.type | journal article | spa |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | d04537ee-c759-486d-9860-07ddf32301d0 | |
| relation.isAuthorOfPublication | 49c11cd7-8122-4e1b-a814-94ac44f3928e | |
| relation.isAuthorOfPublication | 410ff67b-2bce-4f68-97d9-5dcf8d7afc54 | |
| relation.isAuthorOfPublication.latestForDiscovery | d04537ee-c759-486d-9860-07ddf32301d0 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Calvo-Sanz JA Accuracy of Cirrus HD-OCT and Topcon SP-3000P for measuring central corneal thickness.pdf
- Size:
- 720.54 KB
- Format:
- Adobe Portable Document Format
- Description:
- Versión del editor