Clinical Validation of a 3-Dimensional Ultrafast Cardiac Magnetic Resonance Protocol Including Single Breath-Hold 3-Dimensional Sequences

dc.contributor.authorGómez Talavera, Sandra
dc.contributor.authorFernández Jiménez, Rodrigo
dc.contributor.authorFuster, Valentín
dc.contributor.authorNothnagel, Nils D.
dc.contributor.authorKouwenhoven, Marc
dc.contributor.authorGarcía Lunar, Inés
dc.contributor.authorCabrera Rodríguez, José Ángel
dc.contributor.authorPizarro, Gonzalo
dc.contributor.authorIbáñez Cabeza, Borja
dc.contributor.authorSánchez González, Javier
dc.contributor.authorEt al.
dc.date.accessioned2022-06-22T18:48:10Z
dc.date.available2022-06-22T18:48:10Z
dc.date.issued2021
dc.description.abstractObjectives: This study sought to clinically validate a novel 3-dimensional (3D) ultrafast cardiac magnetic resonance (CMR) protocol including cine (anatomy and function) and late gadolinium enhancement (LGE), each in a single breath-hold. Background: CMR is the reference tool for cardiac imaging but is time-consuming. Methods: A protocol comprising isotropic 3D cine (Enhanced sensitivity encoding [SENSE] by Static Outer volume Subtraction [ESSOS]) and isotropic 3D LGE sequences was compared with a standard cine+LGE protocol in a prospective study of 107 patients (age 58 ± 11 years; 24% female). Left ventricular (LV) mass, volumes, and LV and right ventricular (RV) ejection fraction (LVEF, RVEF) were assessed by 3D ESSOS and 2D cine CMR. LGE (% LV) was assessed using 3D and 2D sequences. Results: Three-dimensional and LGE acquisitions lasted 24 and 22 s, respectively. Three-dimensional and LGE images were of good quality and allowed quantification in all cases. Mean LVEF by 3D and 2D CMR were 51 ± 12% and 52 ± 12%, respectively, with excellent intermethod agreement (intraclass correlation coefficient [ICC]: 0.96; 95% confidence interval [CI]: 0.94 to 0.97) and insignificant bias. Mean RVEF 3D and 2D CMR were 60.4 ± 5.4% and 59.7 ± 5.2%, respectively, with acceptable intermethod agreement (ICC: 0.73; 95% CI: 0.63 to 0.81) and insignificant bias. Both 2D and 3D LGE showed excellent agreement, and intraobserver and interobserver agreement were excellent for 3D LGE. Conclusions: ESSOS single breath-hold 3D CMR allows accurate assessment of heart anatomy and function. Combining ESSOS with 3D LGE allows complete cardiac examination in <1 min of acquisition time. This protocol expands the indication for CMR, reduces costs, and increases patient comfort.spa
dc.description.filiationUEMspa
dc.description.impact16.051 JCR (2021) Q1, 9/143 Cardiac & Cardiovascular Systemsspa
dc.description.impact5.914 SJR (2021) Q1, 5/356 Cardiology and Cardiovascular Medicinespa
dc.description.impactNo data IDR 2021spa
dc.description.sponsorshipSalud Carlos III (ISCIII) and the European Regional Development Fund (ERDF) (DTS17/00136, PI19/01704)spa
dc.description.sponsorshipSpanish Society of Cardiology Translational Research Grant 2016 European Research Council (ERC-CoG 819775)spa
dc.description.sponsorshipComunidad de Madrid (S2017/BMD-3867-RENIM-CM)spa
dc.description.sponsorshipMinisterio de Ciencia e Innovación (MICINN) (RETOS2019-107332RB-I00)spa
dc.identifier.citationGómez-Talavera, S., Fernández-Jiménez, R., Fuster, V., Nothnagel, N. D., Kouwenhoven, M., Clemence, M., García-Lunar, I., Gómez-Rubín, M. C., Navarro, F., Pérez-Asenjo, B., Fernández-Friera, L., Calero, M. J., Orejas, M., Cabrera, J. A., Desco, M., Pizarro, G., Ibáñez, B., & Sánchez-González, J. (2021). Clinical Validation of a 3-Dimensional Ultrafast Cardiac Magnetic Resonance Protocol Including Single Breath-Hold 3-Dimensional Sequences. JACC. Cardiovascular Imaging, 14(9), 1742–1754. https://doi.org/10.1016/j.jcmg.2021.02.031spa
dc.identifier.doi10.1016/j.jcmg.2021.02.031
dc.identifier.issn1936-878X
dc.identifier.issn1876-7591
dc.identifier.urihttp://hdl.handle.net/11268/11374
dc.language.isoengspa
dc.peerreviewedSispa
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/FP7/70764spa
dc.relation.publisherversionhttps://doi.org/10.1016/j.jcmg.2021.02.031spa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopen accessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subject.otherImagen por resonancia magnéticaspa
dc.subject.otherGadoliniospa
dc.subject.unescoSistema cardiovascularspa
dc.subject.unescoMedicina preventivaspa
dc.subject.unescoTecnología médicaspa
dc.titleClinical Validation of a 3-Dimensional Ultrafast Cardiac Magnetic Resonance Protocol Including Single Breath-Hold 3-Dimensional Sequencesspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublication6cd3121b-8f38-4779-bc80-293adb5d3566
relation.isAuthorOfPublicationa39ba113-54a7-4611-8ba4-03c7bbd51a03
relation.isAuthorOfPublicationd7955ca2-f5c0-4cac-9981-904be533e7cd
relation.isAuthorOfPublication.latestForDiscovery6cd3121b-8f38-4779-bc80-293adb5d3566

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
García_Cabrera_Pizarro_JACCCI_2021.pdf
Size:
2.43 MB
Format:
Adobe Portable Document Format
Description:
Versión del editor