Analysis of corneal stromal roughness after iFS 150 kHz and LenSx femtosecond LASIK flap creation in porcine eyes

dc.contributor.authorGros Otero, Juan
dc.contributor.authorKetabi, Samira
dc.contributor.authorCañones Zafra, Rafael
dc.contributor.authorGarcía González, Montserrat
dc.contributor.authorParafita Fernández, Alberto
dc.contributor.authorVilla Collar, César
dc.contributor.authorCasado, Santiago
dc.contributor.authorTeus Guezala, Miguel A.
dc.date.accessioned2020-03-05T19:20:39Z
dc.date.available2020-03-05T19:20:39Z
dc.date.issued2019
dc.description.abstractPurpose To describe and compare the stromal bed roughness obtained after laser in situ keratomileusis (LASIK) flap creation using a corneal femtosecond laser platform (iFS 150) and a “dual” femtosecond (FS) laser platform (LenSx). Methods This ex vivo experimental study was conducted in an animal model using 12 freshly enucleated porcine eyes, six with each femtosecond laser. The standard laser treatment parameters were used for the experiment. After LASIK flap creation, the corneal stromal roughness was assessed using atomic force microscopy (AFM) in contact mode immersed in liquid. In each sample, surface measurements were obtained in 60 regions of six eyes per FS laser in 10 20 × 20-micron areas of the central corneal stroma at 512 × 512-point resolution. The surface roughness was measured and the root-mean-square (RMS) values of the roughness were obtained. Results The mean RMS ± standard deviation values were 430 ± 150 nm for the corneal femtosecond laser platform and 370 ± 100 nm for the dual FS laser platform (P < 0.011). Conclusions In this experimental study with AFM, we found smoother stromal beds after LASIK flap creation with LenSx compared to iFS 150 kHz. Further studies are needed to understand visual implications of the differences found.spa
dc.description.filiationUEMspa
dc.description.impactNo data JCR 2019spa
dc.description.impact1.265 SJR (2019) Q1, 16/124 Ophthalmology; Q2, 11/43 Sensory Systems; Q3, 45/89 Cellular and Molecular Neurosciencespa
dc.description.impactNo data IDR 2019spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationGros-Otero, J., Ketabi, S., Cañones-Zafra, R., Garcia-Gonzalez, M., Parafita-Fernandez, A., Villa-Collar, C., Casado, S., & Teus, M. (2019). Analysis of corneal stromal roughness after iFS 150 kHz and LenSx femtosecond LASIK flap creation in porcine eyes. Graefe’s Archive for Clinical and Experimental Ophthalmology, 257(12), 2665-2670. https://doi.org/10.1007/s00417-019-04497-7spa
dc.identifier.doi10.1007/s00417-019-04497-7
dc.identifier.issn0721-832X
dc.identifier.issn1435-702X
dc.identifier.urihttp://hdl.handle.net/11268/8695
dc.language.isoengspa
dc.peerreviewedSispa
dc.relation.publisherversionhttp://ezproxy.universidadeuropea.es/login?url=http://dx.doi.org/10.1007/s00417-019-04497-7spa
dc.rights.accessRightsrestricted accessspa
dc.subject.uemOftalmologíaspa
dc.subject.uemCirugía láserspa
dc.subject.unescoOftalmologíaspa
dc.subject.unescoRayo láserspa
dc.subject.unescoCirugíaspa
dc.titleAnalysis of corneal stromal roughness after iFS 150 kHz and LenSx femtosecond LASIK flap creation in porcine eyesspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublicatione19cbc49-41e7-4085-8afe-3e6d6a1608eb
relation.isAuthorOfPublication.latestForDiscoverye19cbc49-41e7-4085-8afe-3e6d6a1608eb

Files