Ultrasound evaluation of intrinsic plantar muscles and fascia in hallux valgus: A case-control study
| dc.contributor.author | Calvo Lobo, César | |
| dc.contributor.author | Garrido Marín, Alejandro | |
| dc.contributor.author | Rodríguez Sanz, David | |
| dc.contributor.author | López López, Daniel | |
| dc.contributor.author | Palomo López, Patricia | |
| dc.contributor.author | Romero Morales, Carlos | |
| dc.contributor.author | Sanz Corbalán, Irene | |
| dc.date.accessioned | 2017-11-04T15:24:08Z | |
| dc.date.available | 2017-11-04T15:24:08Z | |
| dc.date.issued | 2016 | |
| dc.description.abstract | A cross-sectional area (CSA) and thickness reduction of the abductor hallucis (AbH) is shown in subjects with hallux valgus (HV). To date, other soft-tissue structures have not been researched in relation with HV. The aim of this study was to compare the CSA and thickness of the intrinsic plantar muscles and fascia (PF) between feet with and without HV. Therefore, a cross-sectional and case-control study was performed using B-mode with an iU22 Philips ultrasound system and a 5 to 17-MHz transducer. The CSA and thickness were measured for the AbH, flexor digitorum brevis (FDB) and flexor hallucis brevis (FHB), and also the thickness for the anterior, middle, and posterior PF portions. A convenience sample of 40 feet, 20 with HV and 20 without HV, was recruited from a clinical and research center. A multivariate regression analysis using linear regression was performed to evaluate the ultrasound imaging measurements (α = 0.05). Consequently, statistically significant differences were observed between the groups (P < 0.05) for the AbH and FHB thickness, and CSA reduction, and also the plantar fascia thickness increase in favor of the HV group. On the contrary, the FDB thickness and CSA did not show statistically significant differences (P ≥ 0.05). In conclusion, the CSA and thickness of the AbH and FHB intrinsic plantar muscles are reduced, whereas the thickness of the anterior, middle, and posterior PF portions are increased, in subjects with HV compared with those without HV. | spa |
| dc.description.filiation | UEM | spa |
| dc.description.impact | 1.804 JCR (2016) Q2, 57/155 Medicine, General & Internal | spa |
| dc.description.impact | 0.639 SJR (2016) Q2, 1039/2886 Medicine (miscellaneous) | spa |
| dc.description.impact | No data IDR 2016 | spa |
| dc.description.sponsorship | Sin financiación | spa |
| dc.identifier.citation | Lobo, C. C., Marín, A. G., Sanz, D. R., López, D. L., López, P. P., Morales, C. R., & Corbalán, I. S. (2016). Ultrasound evaluation of intrinsic plantar muscles and fascia in hallux valgus: A case-control study. Medicine, 95(45), e5243. | spa |
| dc.identifier.doi | 10.1097/MD.0000000000005243 | |
| dc.identifier.issn | 00257974 | |
| dc.identifier.issn | 15365964 | |
| dc.identifier.uri | http://hdl.handle.net/11268/6702 | |
| dc.language.iso | eng | spa |
| dc.peerreviewed | Si | spa |
| dc.rights.accessRights | open access | spa |
| dc.subject.other | Hallus vagus | spa |
| dc.subject.uem | Podología | spa |
| dc.subject.unesco | Calidad de vida | spa |
| dc.subject.unesco | Microondas | spa |
| dc.subject.unesco | Medicina preventiva | spa |
| dc.title | Ultrasound evaluation of intrinsic plantar muscles and fascia in hallux valgus: A case-control study | spa |
| dc.type | journal article | spa |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 224f44e5-15ae-48f2-8e32-ac0879c24e79 | |
| relation.isAuthorOfPublication | e18edfdc-00fc-486a-bbac-1eba630d54ec | |
| relation.isAuthorOfPublication | 43641780-6ebb-488f-8857-532d1133ace6 | |
| relation.isAuthorOfPublication | f7e55b2b-699c-4e9e-b57a-d4faaee07ffe | |
| relation.isAuthorOfPublication.latestForDiscovery | 224f44e5-15ae-48f2-8e32-ac0879c24e79 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- medi-95-e5243.pdf
- Size:
- 342.92 KB
- Format:
- Adobe Portable Document Format
- Description:
- Versión del editor

