Ultrasound evaluation of intrinsic plantar muscles and fascia in hallux valgus: A case-control study

dc.contributor.authorCalvo Lobo, César 
dc.contributor.authorGarrido Marín, Alejandro
dc.contributor.authorRodríguez Sanz, David
dc.contributor.authorLópez López, Daniel
dc.contributor.authorPalomo López, Patricia
dc.contributor.authorRomero Morales, Carlos
dc.contributor.authorSanz Corbalán, Irene
dc.date.accessioned2017-11-04T15:24:08Z
dc.date.available2017-11-04T15:24:08Z
dc.date.issued2016
dc.description.abstractA cross-sectional area (CSA) and thickness reduction of the abductor hallucis (AbH) is shown in subjects with hallux valgus (HV). To date, other soft-tissue structures have not been researched in relation with HV. The aim of this study was to compare the CSA and thickness of the intrinsic plantar muscles and fascia (PF) between feet with and without HV. Therefore, a cross-sectional and case-control study was performed using B-mode with an iU22 Philips ultrasound system and a 5 to 17-MHz transducer. The CSA and thickness were measured for the AbH, flexor digitorum brevis (FDB) and flexor hallucis brevis (FHB), and also the thickness for the anterior, middle, and posterior PF portions. A convenience sample of 40 feet, 20 with HV and 20 without HV, was recruited from a clinical and research center. A multivariate regression analysis using linear regression was performed to evaluate the ultrasound imaging measurements (α = 0.05). Consequently, statistically significant differences were observed between the groups (P < 0.05) for the AbH and FHB thickness, and CSA reduction, and also the plantar fascia thickness increase in favor of the HV group. On the contrary, the FDB thickness and CSA did not show statistically significant differences (P ≥ 0.05). In conclusion, the CSA and thickness of the AbH and FHB intrinsic plantar muscles are reduced, whereas the thickness of the anterior, middle, and posterior PF portions are increased, in subjects with HV compared with those without HV.spa
dc.description.filiationUEMspa
dc.description.impact1.804 JCR (2016) Q2, 57/155 Medicine, General & Internalspa
dc.description.impact0.639 SJR (2016) Q2, 1039/2886 Medicine (miscellaneous)spa
dc.description.impactNo data IDR 2016spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationLobo, C. C., Marín, A. G., Sanz, D. R., López, D. L., López, P. P., Morales, C. R., & Corbalán, I. S. (2016). Ultrasound evaluation of intrinsic plantar muscles and fascia in hallux valgus: A case-control study. Medicine, 95(45), e5243.spa
dc.identifier.doi10.1097/MD.0000000000005243
dc.identifier.issn00257974
dc.identifier.issn15365964
dc.identifier.urihttp://hdl.handle.net/11268/6702
dc.language.isoengspa
dc.peerreviewedSispa
dc.rights.accessRightsopen accessspa
dc.subject.otherHallus vagusspa
dc.subject.uemPodologíaspa
dc.subject.unescoCalidad de vidaspa
dc.subject.unescoMicroondasspa
dc.subject.unescoMedicina preventivaspa
dc.titleUltrasound evaluation of intrinsic plantar muscles and fascia in hallux valgus: A case-control studyspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublication224f44e5-15ae-48f2-8e32-ac0879c24e79
relation.isAuthorOfPublicatione18edfdc-00fc-486a-bbac-1eba630d54ec
relation.isAuthorOfPublication43641780-6ebb-488f-8857-532d1133ace6
relation.isAuthorOfPublicationf7e55b2b-699c-4e9e-b57a-d4faaee07ffe
relation.isAuthorOfPublication.latestForDiscovery224f44e5-15ae-48f2-8e32-ac0879c24e79

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
medi-95-e5243.pdf
Size:
342.92 KB
Format:
Adobe Portable Document Format
Description:
Versión del editor