Vault changes after cyclopentolate instillation in eyes with posterior chamber phakic intraocular lens

dc.contributor.authorGargallo Martínez, Beatriz
dc.contributor.authorGarcía Medina, José Javier
dc.contributor.authorRubio Velázquez, Elena
dc.contributor.authorFernandes, Paulo
dc.contributor.authorVilla Collar, César
dc.contributor.authorGonzález Méijome, José Manuel
dc.contributor.authorGutiérrez Ortega, Ángel Ramón
dc.date.accessioned2020-07-07T15:48:57Z
dc.date.available2020-07-07T15:48:57Z
dc.date.issued2020
dc.description.abstractPosterior chamber phakic intraocular lens (pIOL) implantation is a common option for correcting moderate-to-high ocular refractive defects. Because this pIOL is implanted on ciliary sulcus, the distance between the back surface of the pIOL and the anterior surface of the crystalline lens, that it is known as vault, should be measured in different conditions to ensure the technique’s safety. Cyclopentolate is a drug that dilates the pupil and relaxes accommodation (cycloplegia). It is often used for different ocular examinations and for other medical purposes. However, there is no evidence of the effect of this drug on vault. This study quantified central vault changes associated with cyclopentolate instillation. We measured the vault under normal conditions (pre-cycloplegic instillation) and after instilling cyclopentolate on 39 eyes of 39 patients with implanted pIOL. Our results suggest that cyclopentolate instillation may induce changes to vault in eyes with implanted pIOL. These changes seem safe and are mainly associated with vault under normal conditions, but also with anterior chamber depth, pupillary diameter and pIOL size.spa
dc.description.filiationUEMspa
dc.description.impact4.380 JCR (2020) Q1, 17/72 Multidisciplinary Sciencesspa
dc.description.impact1.240 SJR (2020) Q1, 10/135 Multidisciplinaryspa
dc.description.impactNo data IDR 2020spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationGargallo-Martínez, B., García-Medina, J. J., Rubio-Velázquez, E., Fernandes, P., Villa-Collar, C., González-Méijome, J. M., & Gutiérrez-Ortega, R. (2020). Vault changes after cyclopentolate instillation in eyes with posterior chamber phakic intraocular lens. Scientific Reports, 10(1), 9646. https://doi.org/10.1038/s41598-020-66146-yspa
dc.identifier.doi10.1038/s41598-020-66146-y
dc.identifier.issn2045-2322
dc.identifier.urihttp://hdl.handle.net/11268/9022
dc.language.isoengspa
dc.peerreviewedSispa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopen accessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subject.uemOftalmologíaspa
dc.subject.uemTecnología médicaspa
dc.subject.unescoOftalmologíaspa
dc.subject.unescoTecnología médicaspa
dc.titleVault changes after cyclopentolate instillation in eyes with posterior chamber phakic intraocular lensspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublicatione19cbc49-41e7-4085-8afe-3e6d6a1608eb
relation.isAuthorOfPublicationa869dadf-d0fb-4cdd-a7be-42ca9cdcec8c
relation.isAuthorOfPublication.latestForDiscoverye19cbc49-41e7-4085-8afe-3e6d6a1608eb

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Villa_Collar_Nature_2020.pdf
Size:
1.46 MB
Format:
Adobe Portable Document Format
Description:
Versión del editor