dc.description.abstractPurpose: The purpose of this prospective study is to evaluate the relationship between implant diameter, and primary and secondary stability. Materials and methods: Five hundred fifty-nine implants with diameters of 3.7, 4.0, and 4.3 mm and lengths of 10 and 11.5 mm were placed in 195 patients. The resonance frequency was measured during surgery and at 3, 6, and 12 months. Results: Related average implant stability quotient (ISQ) values were 69.62 for 3.7-mm implants, 72.02 for 4.0-mm implants, and 69.67 for 4.3-mm implants. Values in men were greater than values in women. Values were greater for the mandible than for the maxilla. There are significant differences between 4.0-mm implants, and 3.7 anterior maxilla and 4.3 posterior maxilla. Conclusions: There is no relationship between increased ISQ values and increased diameters. We observed a preference regarding sex, with men having significantly greater values for 3.7- and 4.3-mm diameters. The mandible obtained the greatest ISQ values, with significant differences for diameters 3.7 and 4.3 mm.spa
dc.description.filiationUEMspa
dc.description.impact1.452 JCR (2019) Q3, 64/91 Dentistry, Oral Surgery & Medicinespa
dc.description.impact0.743 SJR (2019) Q2, 17/49 Oral Surgeryspa
dc.description.impactNo data IDR 2019spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationAragoneses, J. M., Suárez, A., Arlette Brugal, V., & Gómez, M. (2019). Frequency Values and Their Relationship With the Diameter of Dental Implants: Prospective Study of 559 Implants. Implant Dentistry, 28(3), 279-288. https://doi.org/10.1097/ID.0000000000000887spa
dc.identifier.doi10.1097/ID.0000000000000887
dc.identifier.issn1056-6163
dc.identifier.urihttp://hdl.handle.net/11268/9118
dc.language.isoengspa
dc.peerreviewedSispa
dc.relation.publisherversionhttps://doi.org/10.1097/ID.0000000000000887spa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.accessRightsopen accessspa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subject.uemImplantes dentalesspa
dc.subject.uemAtención odontológicaspa
dc.subject.unescoMaterial sanitariospa
dc.subject.unescoOdontologíaspa
dc.titleFrequency Values and Their Relationship With the Diameter of Dental Implants: Prospective Study of 559 Implantsspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublication5b4560dd-f76a-48c2-a526-0e7dc9183ed5
relation.isAuthorOfPublicationdba1665c-a621-4877-9c02-0b793b29330c
relation.isAuthorOfPublication.latestForDiscovery5b4560dd-f76a-48c2-a526-0e7dc9183ed5

Files