Complicaciones infecciosas relacionadas con la asistencia circulatoria mecánica de corta duración en candidatos a trasplante cardiaco urgente

dc.contributor.authorSolla Buceta, Miguel
dc.contributor.authorGonzález Vílchez, Francisco
dc.contributor.authorAlmenar Bonet, Luis
dc.contributor.authorLambert Rodríguez, José Luis
dc.contributor.authorSegovia Cubero, Javier
dc.contributor.authorGonzález Costello, José
dc.contributor.authorDelgado Jiménez, Juan
dc.contributor.authorPérez Villa, Félix
dc.contributor.authorMartínez Sellés Oliveria Soares, Manuel
dc.contributor.authorBarge Caballero, Eduardo
dc.contributor.authorEt al.
dc.date.accessioned2021-02-11T16:44:26Z
dc.date.available2021-02-11T16:44:26Z
dc.date.issued2022
dc.description.abstractIntroducción y objetivos El uso de dispositivos de asistencia circulatoria mecánica de corta duración como puente a trasplante es frecuente en España. Se desconocen la epidemiología y la repercusión de las complicaciones infecciosas en estos pacientes. Métodos Descripción sistemática de la epidemiología y análisis de la repercusión pronóstica de las complicaciones infecciosas en un registro multicéntrico retrospectivo de pacientes tratados con dispositivos de asistencia circulatoria mecánica de corta duración como puente a trasplante cardiaco urgente entre 2010 y 2015 en 16 hospitales españoles. Resultados Se estudió a 249 pacientes; 87 (34,9%) de ellos tuvieron un total de 102 infecciones. La vía respiratoria fue la localización más frecuente (n = 47; 46,1%). En 78 casos (76,5%) se obtuvo confirmación microbiológica; se aislaron en total 100 gérmenes causales, con predominio de bacterias gramnegativas (n = 58, 58%). Los pacientes con complicaciones infecciosas presentaron mayor mortalidad durante el periodo de asistencia circulatoria mecánica (el 25,3 frente al 12,3%; p = 0,009) y menor probabilidad de recibir un trasplante (el 73,6 frente al 85,2%; p = 0,025) que los pacientes sin infección. La mortalidad posoperatoria tras el trasplante fue similar en ambos grupos (con infección, el 28,3%; sin infección, el 23,4%; p = 0,471). Conclusiones Los pacientes tratados con dispositivos de asistencia circulatoria mecánica de corta duración como puente al trasplante cardiaco están expuestos a un alto riesgo de complicaciones infecciosas, las cuales se asocian con una mayor mortalidad en espera del órgano.spa
dc.description.abstractIntroduction and objectives Short-term mechanical circulatory support is frequently used as a bridge to heart transplant in Spain. The epidemiology and prognostic impact of infectious complications in these patients are unknown. Methods Systematic description of the epidemiology of infectious complications and analysis of their prognostic impact in a multicenter, retrospective registry of patients treated with short-term mechanical devices as a bridge to urgent heart transplant from 2010 to 2015 in 16 Spanish hospitals. Results We studied 249 patients, of which 87 (34.9%) had a total of 102 infections. The most frequent site was the respiratory tract (n = 47; 46.1%). Microbiological confirmation was obtained in 78 (76.5%) episodes, with a total of 100 causative agents, showing a predominance of gram-negative bacteria (n = 58, 58%). Compared with patients without infection, those with infectious complications showed higher mortality during the support period (25.3% vs 12.3%, P = .009) and a lower probability of receiving a transplant (73.6% vs 85.2%, P = .025). In-hospital posttransplant mortality was similar in the 2 groups (with infection: 28.3%; without infection: 23.4%; P = .471). Conclusions Patients supported with temporary devices as a bridge to heart transplant are exposed to a high risk of infectious complications, which are associated with higher mortality during the organ waiting period.spa
dc.description.filiationUEMspa
dc.description.impact5.9 Q1 JCR 2022spa
dc.description.impact0.463 Q3 SJR 2022spa
dc.description.impactNo data IDR 2022spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationSolla-Buceta, M., González-Vílchez, F., Almenar-Bonet, L., Lambert-Rodríguez, J. L., Segovia-Cubero, J., González-Costello, J., Delgado, J. F., Pérez-Villa, F., Crespo-Leiro, M. G., Rangel-Sousa, D., Martínez-Sellés, M., Rábago-Juan-Aracil, G., Fuente-Galán, L., Blasco-Peiró, T., Hervás-Sotomayor, D., Garrido-Bravo, I. P., Mirabet-Pérez, S., Muñiz, J., y Barge-Caballero, E. (2022). Complicaciones infecciosas relacionadas con la asistencia circulatoria mecánica de corta duración en candidatos a trasplante cardiaco urgente. Revista Española de Cardiología, 75(2), 141-149. https://doi.org/10.1016/j.recesp.2020.11.011spa
dc.identifier.doi10.1016/j.recesp.2020.11.011
dc.identifier.issn1579-2242
dc.identifier.issn0300-8932
dc.identifier.urihttp://hdl.handle.net/11268/9839
dc.language.isospaspa
dc.peerreviewedSispa
dc.rights.accessRightsrestricted accessspa
dc.subject.otherInsuficiencia cardíacaspa
dc.subject.otherTrasplante de órganosspa
dc.subject.otherInfeccionesspa
dc.subject.unescoEnfermedad cardiovascularspa
dc.subject.unescoAparato respiratoriospa
dc.subject.unescoTrasplante de órganosspa
dc.titleComplicaciones infecciosas relacionadas con la asistencia circulatoria mecánica de corta duración en candidatos a trasplante cardiaco urgentespa
dc.title.alternativeInfectious complications associated with short-term mechanical circulatory support in urgent heart transplant candidatesspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublicationa14a4cbe-6878-47e7-8b7b-ffdd4a82573a
relation.isAuthorOfPublication.latestForDiscoverya14a4cbe-6878-47e7-8b7b-ffdd4a82573a

Files