Effect of platform switching on the peri-implant bone: A finite element study

dc.contributor.authorBouazza Juanes, Kheira
dc.contributor.authorMartínez González, María Amparo
dc.contributor.authorPeiró, Germán
dc.contributor.authorRódenas García, Juan José
dc.contributor.authorLópez Mollá, Victoria
dc.date.accessioned2017-10-31T08:38:10Z
dc.date.available2017-10-31T08:38:10Z
dc.date.issued2015
dc.description.abstractThere exists a relation between the presence and location of the micro-gap and the loss of peri implant bone. Several authors have shown that the treatments based on the use of platform switching result in less peri-implant bone loss and an increased tissue stability. The purpose of this study was to analyse the effect of the platform switching on the distribution of stresses on the peri-implant bone using the finite element method. A realistic 3D full-mandible finite element model representing cortical bone and trabecular bone was used to study the distribution of the stress on the bone induced by an implant of diameter 4.1 mm. Two abutments were modelled. The first one, of diameter 4.1 mm, was used in the reference model to represent a conventional implant. The second one, of diameter 3.2 mm, was used to represent the implant with platform switching. Both models were subjected to axial and oblique masticatory loads. The analyses showed that, although no relevant differences can be found for the trabecular bone, the use of platform switching reduces the maximum stress level in the cortical bone by almost 36% with axial loads and by 40% with oblique loads. The full 3D Finite Element model, that can be used to investigate the influence of other parameters (implant diameter, connexion type, …) on the biomechanical behaviour of the implant, showed that this stress reduction can be a biomechanical reasons to explain why the platform switching seems to reduce or eliminate crestal bone resorption after the prosthetic restoration.spa
dc.description.filiationUEVspa
dc.description.impactNo data (2016)spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationBouazza-Juanes, K., Martínez-González, A., Peiró, G., Ródenas, J. J., & López-Mollá, M. V. (2015). Effect of platform switching on the peri-implant bone: A finite element study. Journal of clinical and experimental dentistry, 7(4), e483. DOI: 10.4317/jced.52539spa
dc.identifier.doi10.4317/jced.52539
dc.identifier.issn19895488
dc.identifier.urihttp://hdl.handle.net/11268/6664
dc.language.isoengspa
dc.peerreviewedSispa
dc.relation.publisherversionhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4628802/pdf/jced-7-e483.pdfspa
dc.rights.accessRightsopen accessspa
dc.subject.uemImplantes dentalesspa
dc.subject.uemOsteólisisspa
dc.subject.unescoOdontologíaspa
dc.titleEffect of platform switching on the peri-implant bone: A finite element studyspa
dc.typejournal articlespa