The concurrent validity and reliability of the Leg Motion system for measuring ankle dorsiflexion range of motion in older adults

dc.contributor.authorRomero Morales, Carlos
dc.contributor.authorCalvo Lobo, César 
dc.contributor.authorRodríguez Sanz, David
dc.contributor.authorSanz Corbalán, Irene
dc.contributor.authorRuiz Ruiz, Beatriz
dc.contributor.authorLópez López, Daniel
dc.date.accessioned2019-05-14T18:25:37Z
dc.date.available2019-05-14T18:25:37Z
dc.date.issued2017
dc.description.abstractBackground New reliable devices for range of motion (ROM) measures in older adults are necessary to improve knowledge about the functional capability in this population. Dorsiflexion ROM limitation is associated with ankle injuries, foot pain, lower limb disorders, loss of balance, gait control disorders and fall risk in older adults. The aim of the present study was to assess the validity and reliability of the Leg Motion device for measuring ankle dorsiflexion ROM in older adults. Methods Adescriptive repeated-measures study was designed to test the reliability of Leg Motion in thirty-three healthy elderly patients older than 65 years. The subjects had to meet the following inclusion and exclusion criteria in their medical records: older than 65 years; no lower extremity injury for at least one year prior to evaluation (meniscopathy, or fractures) and any chronic injuries (e.g., osteoarthritis); no previous hip, knee or ankle surgery; no neuropathic alterations and no cognitive conditions (e.g., Alzheimer’s disease or dementia). Participants were recruited through the person responsible for the physiotherapist area from a nursing center. The subjects were evaluated in two different sessions at the same time of day, and there was a break of two weeks between sessions. To test the validity of the Leg Motion system, the participants were measured in a weight-bearing lunge position using a classic goniometer with 1° increments, a smartphone with an inclinometer standard app (iPhone 5S®) with 1° increments and a measuring tape that could measure 0.1 cm. All testing was performed while the patients were barefoot. The researcher had ten years of experience as a physiotherapist using goniometer, tape measure and inclinometer devices. Results Mean values and standard deviations were as follows: Leg Motion (right 5.15 ± 3.08; left 5.19 ± 2.98), tape measure (right 5.12 ± 3.08; left 5.12 ± 2.80), goniometer (right 45.87° ± 4.98; left 44.50° ± 5.54) and inclinometer app (right 46.53° ± 4.79; left 45.27° ± 5.19). The paired t-test showed no significant differences between the limbs or between the test and re-test values. The test re-test reliability results for Leg Motion were as follows: the standard error of the measurement ranged from 0.29 to 0.43 cm, the minimal detectable difference ranged from 0.79 to 1.19 cm, and the intraclass correlation coefficients (ICC) values ranged from 0.97 to 0.98. Conclusions The results of the present study indicated that the Leg Motion device is a valid, reliable, accessible and portable tool as an alternative to the classic weight-bearing lunge test for measuring ankle dorsiflexion ROM in older adultsspa
dc.description.filiationUEMspa
dc.description.impact2.118 JCR (2017) Q2, 19/64 Multidisciplinary Sciencesspa
dc.description.impact1.087 SJR (2017) Q1, 34/285 Agricultural and Biological Sciences (miscellaneous), 53/255 Biochemistry, Genetics and Molecular Biology (miscellaneous), 513/2878 Medicine (miscellaneous); Q2, 62/159 Neuroscience (miscellaneous)spa
dc.description.impactNo data IDR 2017spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationMorales, C. R., Lobo, C. C., Sanz, D. R., Corbalán, I. S., Ruiz, B. R., & López, D. L. (2017). The concurrent validity and reliability of the Leg Motion system for measuring ankle dorsiflexion range of motion in older adults. PeerJ, 5, e2820. https://doi.org/10.7717/peerj.2820spa
dc.identifier.doi10.7717/peerj.2820
dc.identifier.issn2376-5992
dc.identifier.urihttp://hdl.handle.net/11268/7896
dc.language.isoengspa
dc.peerreviewedSispa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacionalen
dc.rights.accessRightsopen accessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/en
dc.subject.uemMotricidadspa
dc.subject.uemTecnología médicaspa
dc.subject.uemAncianosspa
dc.subject.unescoFisiología humanaspa
dc.subject.unescoTecnología médicaspa
dc.subject.unescoAncianospa
dc.titleThe concurrent validity and reliability of the Leg Motion system for measuring ankle dorsiflexion range of motion in older adultsspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublicationf7e55b2b-699c-4e9e-b57a-d4faaee07ffe
relation.isAuthorOfPublication224f44e5-15ae-48f2-8e32-ac0879c24e79
relation.isAuthorOfPublication43641780-6ebb-488f-8857-532d1133ace6
relation.isAuthorOfPublication4d806815-3ec3-4bb4-89f5-724c18e3b2c5
relation.isAuthorOfPublication.latestForDiscoveryf7e55b2b-699c-4e9e-b57a-d4faaee07ffe

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
peerj-05-2820.pdf
Size:
7.12 MB
Format:
Adobe Portable Document Format
Description:
Versión del editor