MTA apical barrier: in vitro study of the use of ultrasonic vibration

dc.contributor.authorEscribano Escrivá, Begoña
dc.contributor.authorMicó Muñoz, Pedro
dc.contributor.authorManzano Saiz, Alberto
dc.contributor.authorGiner Lluesma, Teresa
dc.contributor.authorCollado Castellanos, Nicolás
dc.contributor.authorMuwaquet Rodríguez, Susana
dc.date.accessioned2020-06-29T14:11:45Z
dc.date.available2020-06-29T14:11:45Z
dc.date.issued2016
dc.description.abstractBackground: The apexification is the first alternative treatment on a permanent tooth when, after a tooth trauma and in the presence of immature apex trauma, pulp necrosis occurs. Many studies have demonstrated the efficacy of mineral trioxide aggregate (MTA) as apical sealing material of choice in these cases, but has a degree of filtration as all other materials. The objective of this study was to analyze the seal ability of MTA on the duct walls in immature teeth unirradicular apexes, using indirect vibration. Material and Methods: The study was conducted on 45 teeth divided into 3 groups: Group A or control group in which no vibration for placing the MTA was used, Group B and C or groups where indirect vibration analysis was used. All samples were immersed in methylene blue to assess filtration. After performing longitudinal cuts millimetric measuring were made of the degree of filtration, divided into 3 degrees (2mm each grade filtration). Results: Results obtained confirm our hypothesis, obtaining lesser degree of filtration those groups in which indirect vibration (Groups B and C) was performed. It was shown that the degree of filtration is closely linked to the degree of adaptation. Conclusions: MTA vibration offers better results in its adaptation to the canal walls, significantly reducing the degree of filtration.spa
dc.description.filiationUEVspa
dc.description.impact0.49 SJR (2016) Q2, 63/141 Dentistry (miscellaneous)spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationEscribano-Escrivá, B., Micó-Muñoz, P., Manzano-Saiz, A., Giner-Lluesma, T., Collado-Castellanos, N., & Muwaquet-Rodríguez, S. (2016). MTA apical barrier: in vitro study of the use of ultrasonic vibration. Journal of Clinical and Experimental Dentistry, 8(3), e318-e321. https://doi.org/10.4317/jced.53085spa
dc.identifier.doi10.4317/jced.53085
dc.identifier.issn1989-5488
dc.identifier.urihttp://hdl.handle.net/11268/9005
dc.language.isoengspa
dc.peerreviewedSispa
dc.relation.publisherversionhttps://doi.org/10.4317/jced.53085spa
dc.rights.accessRightsopen accessspa
dc.subject.uemMateriales dentalesspa
dc.subject.uemOdontologíaspa
dc.subject.uemUltrasonidos en medicinaspa
dc.subject.unescoOdontologíaspa
dc.subject.unescoTecnología médicaspa
dc.titleMTA apical barrier: in vitro study of the use of ultrasonic vibrationspa
dc.typejournal articlespa
dspace.entity.typePublication

Files