Resumen:
To determine if the discontinuation of commercially-available simultaneous vision Multifocal Soft Contact Lenses is independent from the multifocal design. To determine causes for discontinuation and psychosocial factors involved.
METHODS:
Multicentre single-blinded randomised controlled trial with external blinded evaluation for a three months follow-up period for three intervention groups. 150 single-vision soft wearers were randomly assigned a spherical near centred lens (S-CN), distance centred lens (CD) or aspherical near centred lens (A-CN). Cases of discontinuation, anxiety and quality of life were measured at one week and one month.
RESULTS:
120 females and 30 males were included with an age range of 40-62 (48.79 ± 5.23). At one month, the S-CN design had a statistically significant higher risk of discontinuation than the other two OR: 6.12 (95%CI 2.5-14.9). Twenty-eight subjects discontinued wearing S-CN at first week (56%), while discontinuation of CD and A-CD were 15 (30%) and 11 (22%), with a statistically significant difference between S-CN design and the other two (p = 0.001). There were not statistically significant differences when direct comparison between discontin...