Case Studies in Physiology: Physiological and clinical effects of temporary diaphragm pacing in two patients with ventilator-induced diaphragm dysfunction
Case Studies in Physiology: Physiological and clinical effects of temporary diaphragm pacing in two patients with ventilator-induced diaphragm dysfunction
Ventilator-induced diaphragm dysfunction (VIDD) is increasingly recognized as an important side-effect of invasive ventilation in critically ill patients and is associated with poor outcomes. Whether patients with VIDD benefit from temporary diaphragm pacing is uncertain. Intramuscular diaphragmatic electrodes were implanted for temporary stimulation with a pacing device (TransAeris System) in two patients with VIDD. The electrodes were implanted via laparoscopy (first patient) or via bilateral thoracoscopy (second patient). Stimulation parameters were titrated according to tolerance. Diaphragm thickening fraction by ultrasound, maximum inspiratory pressure (Pimax) and diaphragm electromyography (EMGdi) signal analysis were used to monitor the response to diaphragm pacing. Both patients tolerated diaphragm pacing. In the first patient, improvements in diaphragm excursions were noted once pacing was initiated and diaphragm thickening fraction did not further deteriorate over time. The diaphragm thickening fraction improved in the second patient, and Pimax as well as EMGdi analysis suggested improved muscle function. This patient could be fully weaned from the ventilator. These case reports present...