Mostrar el registro sencillo del ítem
dc.contributor.author | Molinero Mourelle, Pedro | |
dc.contributor.author | Gómez Polo, Miguel | |
dc.contributor.author | Gómez Polo, Cristina | |
dc.contributor.author | Ortega Sánchez, Rocío | |
dc.contributor.author | Río Highsmith, Jaime del | |
dc.contributor.author | Celemín Viñuela, Alicia | |
dc.date.accessioned | 2022-05-12T15:03:24Z | |
dc.date.available | 2022-05-12T15:03:24Z | |
dc.date.issued | 2020 | |
dc.identifier.citation | Molinero-Mourelle, P., Gómez-Polo, M., Gómez-Polo, C., Ortega, R., Río Highsmith, J., & Celemín-Viñuela, A. (2020). Preliminary Study on the Assessment of the Marginal Fit of Three-Dimensional Methacrylate Oligomer Phosphine Oxide Provisional Fixed Dental Prostheses Made by Digital Light Processing. Prosthesis, 2(3), 240–245. https://doi.org/10.3390/prosthesis2030021 | spa |
dc.identifier.issn | 2673-1592 | |
dc.identifier.uri | http://hdl.handle.net/11268/11233 | |
dc.description.abstract | This article aimed to assess the marginal fit of methacrylate-oligomer-phosphine-oxide curable-resin provisional-fixed dental prostheses made by digital-light-processing (DLP) three-dimensional (3D) printing. A stainless-steel master model with two abutments was scanned, and five three-unit provisional bridges were designed and printed in VITA shade A3.5 curable resin in 50 μm-thick layers. The marginal fit of each abutment was measured at six points using a profile projector. A descriptive data analysis of the fit measurements was performed by descriptive and explorative processes with the SPSS software. The curable-resin provisional restorations made by DLP 3D printing reached values of 46.37 μm (SD: 29.58 μm), which were considered clinically acceptable, with values similar to polyethylene-methacrylate and polyether-ether-ketone provisional restorations. | spa |
dc.description.sponsorship | Sin financiación | spa |
dc.language.iso | eng | spa |
dc.rights | Attribution 4.0 International | * |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | * |
dc.subject.other | Prótesis dental | spa |
dc.title | Preliminary Study on the Assessment of the Marginal Fit of Three-Dimensional Methacrylate Oligomer Phosphine Oxide Provisional Fixed Dental Prostheses Made by Digital Light Processing | spa |
dc.type | article | spa |
dc.description.impact | No data JCR 2020 | spa |
dc.description.impact | No data SJR 2020 | spa |
dc.description.impact | No data IDR 2020 | spa |
dc.identifier.doi | 10.3390/prosthesis2030021 | |
dc.rights.accessRights | openAccess | spa |
dc.subject.unesco | Odontología | spa |
dc.subject.unesco | Tecnología médica | spa |
dc.description.filiation | UEM | spa |
dc.peerreviewed | Si | spa |