The use of autonomic modulation device to control training performance after high-intensity interval training program

dc.contributor.authorClemente Suárez, Vicente Javier
dc.contributor.authorArroyo Toledo, Juan Jaime
dc.date.accessioned2018-11-23T15:33:43Z
dc.date.available2018-11-23T15:33:43Z
dc.date.issued2018
dc.description.abstractThe aim of the present research was to analyze the autonomic response in a group of trained swimmers before and after conducting a 4-week period of high-intensity interval training (HIT). Heart rate variability was analyzed in 14 swimmers (16.2 ± 2.6 years, 169.1 ± 10.2 cm and 61.3 ± 9.9 kg) in basal condition and during a HIT session before and after completing a training period. The HIT session that was evaluated consisted of: 16 × 25 m maximum speed, resting 30 s between sets. Participants combined aerobic training with tethered swimming and HIT sessions three times per week in a period of 4 weeks. Results showed a significantly decrease (p < 0.05) of the standard deviation of the NN intervals (SDNN), the standard deviation of differences between adjacent NN intervals (SDSD), the number of successive difference of intervals which differ by more than 50 ms (NN50), after the training period. Results showed a higher parasympathetic activation besides improvements in autonomic adaptation after HIT training period.spa
dc.description.filiationUEMspa
dc.description.impact2.415 JCR (2018) Q2, 41/98 Health Care Sciences & Services, 12/26 Medical Informaticsspa
dc.description.impact0.565 SJR (2018) Q2, 28/163 Health Informatics, 11/57 Health Information Management, 104/941 Information Systems, 1184/2844 Medicine (miscellaneous)spa
dc.description.impactNo data IDR 2018spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationClemente-Suárez, V. J., & Arroyo-Toledo, J. J. (2018). The Use of Autonomic Modulation Device to Control Training Performance after High-Intensity Interval Training Program. Journal of medical systems, 42(3), 47. http:/ /dx.doi.org/10.1007/s10916-018-0907-8spa
dc.identifier.doi10.1007/s10916-018-0907-8
dc.identifier.issn0148-5598
dc.identifier.issn1573-689X
dc.identifier.urihttp://hdl.handle.net/11268/7604
dc.language.isoengspa
dc.peerreviewedSispa
dc.relation.publisherversionhttp://ezproxy.universidadeuropea.es/login?url=http:/ /dx.doi.org/10.1007/s10916-018-0907-8spa
dc.rights.accessRightsrestricted accessspa
dc.subject.uemNataciónspa
dc.subject.uemEntrenamiento deportivo - Aspectos fisiológicosspa
dc.subject.unescoNataciónspa
dc.subject.unescoDesarrollo fisiológicospa
dc.titleThe use of autonomic modulation device to control training performance after high-intensity interval training programspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublicationa2e25626-16b1-41bc-9c67-8de8ce6e007d
relation.isAuthorOfPublication.latestForDiscoverya2e25626-16b1-41bc-9c67-8de8ce6e007d

Files