The use of autonomic modulation device to control training performance after high-intensity interval training program
| dc.contributor.author | Clemente Suárez, Vicente Javier | |
| dc.contributor.author | Arroyo Toledo, Juan Jaime | |
| dc.date.accessioned | 2018-11-23T15:33:43Z | |
| dc.date.available | 2018-11-23T15:33:43Z | |
| dc.date.issued | 2018 | |
| dc.description.abstract | The aim of the present research was to analyze the autonomic response in a group of trained swimmers before and after conducting a 4-week period of high-intensity interval training (HIT). Heart rate variability was analyzed in 14 swimmers (16.2 ± 2.6 years, 169.1 ± 10.2 cm and 61.3 ± 9.9 kg) in basal condition and during a HIT session before and after completing a training period. The HIT session that was evaluated consisted of: 16 × 25 m maximum speed, resting 30 s between sets. Participants combined aerobic training with tethered swimming and HIT sessions three times per week in a period of 4 weeks. Results showed a significantly decrease (p < 0.05) of the standard deviation of the NN intervals (SDNN), the standard deviation of differences between adjacent NN intervals (SDSD), the number of successive difference of intervals which differ by more than 50 ms (NN50), after the training period. Results showed a higher parasympathetic activation besides improvements in autonomic adaptation after HIT training period. | spa |
| dc.description.filiation | UEM | spa |
| dc.description.impact | 2.415 JCR (2018) Q2, 41/98 Health Care Sciences & Services, 12/26 Medical Informatics | spa |
| dc.description.impact | 0.565 SJR (2018) Q2, 28/163 Health Informatics, 11/57 Health Information Management, 104/941 Information Systems, 1184/2844 Medicine (miscellaneous) | spa |
| dc.description.impact | No data IDR 2018 | spa |
| dc.description.sponsorship | Sin financiación | spa |
| dc.identifier.citation | Clemente-Suárez, V. J., & Arroyo-Toledo, J. J. (2018). The Use of Autonomic Modulation Device to Control Training Performance after High-Intensity Interval Training Program. Journal of medical systems, 42(3), 47. http:/ /dx.doi.org/10.1007/s10916-018-0907-8 | spa |
| dc.identifier.doi | 10.1007/s10916-018-0907-8 | |
| dc.identifier.issn | 0148-5598 | |
| dc.identifier.issn | 1573-689X | |
| dc.identifier.uri | http://hdl.handle.net/11268/7604 | |
| dc.language.iso | eng | spa |
| dc.peerreviewed | Si | spa |
| dc.relation.publisherversion | http://ezproxy.universidadeuropea.es/login?url=http:/ /dx.doi.org/10.1007/s10916-018-0907-8 | spa |
| dc.rights.accessRights | restricted access | spa |
| dc.subject.uem | Natación | spa |
| dc.subject.uem | Entrenamiento deportivo - Aspectos fisiológicos | spa |
| dc.subject.unesco | Natación | spa |
| dc.subject.unesco | Desarrollo fisiológico | spa |
| dc.title | The use of autonomic modulation device to control training performance after high-intensity interval training program | spa |
| dc.type | journal article | spa |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | a2e25626-16b1-41bc-9c67-8de8ce6e007d | |
| relation.isAuthorOfPublication.latestForDiscovery | a2e25626-16b1-41bc-9c67-8de8ce6e007d |

