M-Mode Ultrasound Examination of Soleus Muscle in Healthy Subjects: Intra- and Inter-Rater Reliability Study

dc.contributor.authorRomero Morales, Carlos
dc.contributor.authorCalvo Lobo, César 
dc.contributor.authorNavarro Flores, Emmanuel
dc.contributor.authorMazoteras Pardo, Victoria
dc.contributor.authorGarcía Bermejo, Paula
dc.contributor.authorLópez López, Daniel
dc.contributor.authorMartínez Jiménez, Eva María
dc.contributor.authorCruz Torres, Blanca de la
dc.date.accessioned2022-04-01T17:34:12Z
dc.date.available2022-04-01T17:34:12Z
dc.date.issued2020
dc.description.abstractObjective: M-mode ultrasound imaging (US) reflects the motion of connective tissue within muscles. The objectives of this study were to evaluate inter-rater and intra-rater reliability of soleus muscle measurements between examiners with different levels of US experience in asymptomatic subjects and to investigate the level of soleus muscle isometric activity in two positions (knee extended and knee flexed at 30°). Methods: Thirty volunteers without a history of ankle pain were evaluated with US examinations of the soleus muscle. Each muscle was scanned independently by two evaluators. Muscle at rest thickness, maximal isometric contraction thickness, time and velocity measures were detailed and blinded to the other examiner. Results: Intra- and inter-rater reliability at rest, in maximal isometric contraction thickness, contraction time and contraction velocity measures for both positions (extended and flexed knee) were reported from good to excellent for all outcome measurements. The position with the knee extended reported a statistically significant increase in thickness after motion showing 1.33 ± 0.27 mm for measurements at rest thickness with knee extended versus 1.50 ± 0.29 mm for measurements at end thickness with the knee in flexed position (p = 0.001), as well as 1.31 ± 0.23 mm for rest thickness with the knee in flexed position measurements with respect to 1.34 ± 0.24 mm for maximal isometric contraction thickness with extended knee measurements (p = 0.058). Conclusions: This study found that intra- and inter-examiner reliability of M-mode ultrasound imaging of the soleus muscle was excellent in asymptomatic subjects and the soleus muscle activity was different between the position with the knee extended and the position with the knee flexed.spa
dc.description.filiationUEMspa
dc.description.impact2.645 JCR (2020) Q2, 40/88 Health Policy & Servicesspa
dc.description.impactNo data SJR 2020spa
dc.description.impactNo data IDR 2020spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationRomero-Morales, C., Calvo-Lobo, C., Navarro-Flores, E., Mazoteras-Pardo, V., García-Bermejo, P., López-López, D., Martínez-Jiménez, E. M., & Cruz-Torres, B. (2020). M-Mode Ultrasound Examination of Soleus Muscle in Healthy Subjects: Intra- and Inter-Rater Reliability Study. Healthcare, 8(4), 555. https://doi.org/10.3390/healthcare8040555spa
dc.identifier.doi10.3390/healthcare8040555
dc.identifier.issn2227-9032
dc.identifier.urihttp://hdl.handle.net/11268/11002
dc.language.isoengspa
dc.peerreviewedSispa
dc.rightsAtribución 4.0 Internacional*
dc.rights.accessRightsopen accessspa
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subject.otherUltrasonografíaspa
dc.subject.otherMúsculo esqueléticospa
dc.subject.unescoTecnología médicaspa
dc.subject.unescoTrabajo de investigaciónspa
dc.subject.unescoAnálisis de datosspa
dc.titleM-Mode Ultrasound Examination of Soleus Muscle in Healthy Subjects: Intra- and Inter-Rater Reliability Studyspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublicationf7e55b2b-699c-4e9e-b57a-d4faaee07ffe
relation.isAuthorOfPublication224f44e5-15ae-48f2-8e32-ac0879c24e79
relation.isAuthorOfPublication.latestForDiscoveryf7e55b2b-699c-4e9e-b57a-d4faaee07ffe

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Romero_García_Healthcare_2020.pdf
Size:
688.06 KB
Format:
Adobe Portable Document Format
Description:
Versión del editor