Mechanical Performance of Chairside Ceramic CAD/CAM Restorations and Zirconia Abutments with Different Internal Implant Connections: In Vitro Study and Finite Element Analysis

dc.contributor.authorGiner, Sergio
dc.contributor.authorBartolomé, José F.
dc.contributor.authorGómez Cogolludo, Pablo
dc.contributor.authorCastellote Varona, Carlos
dc.contributor.authorPradíes, Guillermo
dc.date.accessioned2021-11-04T18:06:00Z
dc.date.available2021-11-04T18:06:00Z
dc.date.issued2021
dc.description.abstract(computer-aided design-computer-aided manufacturing) CAD/CAM monolithic restorations connected to zirconia abutments manufactured with a chairside workflow are becoming a more common restorative option. However, their mechanical performance is still uncertain. The aim of this study was to evaluate the mechanical behavior of a combination of a zirconia abutment and monolithic all-ceramic zirconia and lithium disilicate crown manufactured with a chairside workflow, connected to titanium implants with two types of internal connection—tube in tube connection and conical connection with platform switching. They were thermally cycled from 5 C to 55 C and were subjected to a static and fatigue test following ISO 14801. The fractured specimens from the fatigue test were examined by SEM (scanning electron microscopy). Simulations of the stress distribution over the different parts of the restorative complex during the mechanical tests were evaluated by means of (finite element analysis) FEA. The mechanical performance of the zirconia abutment with an internal conical connection was higher than that of the tube in tube connection. Additionally, the use of disilicate or zirconia all-ceramic chairside CAD/CAM monolithic restorations has similar results in terms of mechanical fracture and fatigue resistance. Stress distribution affects the implant/restoration complex depending on the connection design. Zirconia abutments and monolithic restorations seem to be highly reliable in terms of mechanical resistance.spa
dc.description.filiationUEMspa
dc.description.impact3.748 JCR (2021) Q1, 18/79 Metallurgy & Metallurgical Engineeringspa
dc.description.impact0.604 SJR (2021) Q2, 212/591 Materials Science (miscellaneous)spa
dc.description.impactNo data IDR 2021spa
dc.description.sponsorshipSin financiaciónspa
dc.identifier.citationGiner, S., Bartolomé, J. F., Gómez-Cogolludo, P., Castellote, C., & Pradíes, G. (2021). Mechanical Performance of Chairside Ceramic CAD/CAM Restorations and Zirconia Abutments with Different Internal Implant Connections: In Vitro Study and Finite Element Analysis. Materials, 14(17), 5009. https://doi.org/10.3390/ma14175009spa
dc.identifier.doi10.3390/ma14175009
dc.identifier.issn1996-1944
dc.identifier.urihttp://hdl.handle.net/11268/10453
dc.language.isoengspa
dc.peerreviewedSispa
dc.rightsAttribution 4.0 Internacional*
dc.rights.accessRightsopen accessspa
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subject.otherMateriales dentalesspa
dc.subject.otherImplantación dentalspa
dc.subject.otherDiseño asistido por computadoraspa
dc.subject.unescoOdontologíaspa
dc.subject.unescoTecnología médicaspa
dc.titleMechanical Performance of Chairside Ceramic CAD/CAM Restorations and Zirconia Abutments with Different Internal Implant Connections: In Vitro Study and Finite Element Analysisspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublication9a2aa3de-e329-46ec-9440-38e2f1828fcd
relation.isAuthorOfPublication.latestForDiscovery9a2aa3de-e329-46ec-9440-38e2f1828fcd

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Castellote_materials_2021.pdf
Size:
4.54 MB
Format:
Adobe Portable Document Format
Description:
Versión del editor