Clinical characteristics and outcomes of aortic prosthetic valve endocarditis: comparison between transcatheter and surgical bioprostheses

Loading...
Thumbnail Image
Identifiers

Publication date

Authors

Jeronimo, Adrián
Zulet, Pablo
Gómez Ramírez, Daniel
Anguita, Manuel

Advisors

Editors

Journal Title

Journal ISSN

Volume Title

Publisher

SDG

goal-3

Metrics

Google Scholar

Research Projects

Organizational Units

Journal Issue

Abstract

Most data regarding infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) comes from TAVI registries, rather than IE dedicated cohorts. The objective of this study is to compare the clinical and microbiological profile, imaging features and outcomes of patients with IE after SAVR with a biological prosthetic valve (IE-SAVR) and IE after TAVI (IE-TAVI) from 6 centres with an Endocarditis Team (ET) and broad experience in IE through a retrospective analysis of prospectively collected data

Description

Keywords

Bibliographic reference

Jerónimo, A., Olmos, C., Zulet, P., Gómez-Ramírez, D., Anguita, M., Carlos Castillo, J., Escrihuela-Vidal, F., Cuervo, G., Calderón-Parra, J., Ramos, A., Cabezón, G., Álvarez Rodríguez, J., Pulido, P., De Miguel-Álava, M., Sáez, C., López, J., Vilacosta, I., & San Román, J. A. (2024). Clinical characteristics and outcomes of aortic prosthetic valve endocarditis: Comparison between transcatheter and surgical bioprostheses. Infection, 52(6), 2425-2434. https://doi.org/10.1007/s15010-024-02302-0

Type of document

Attribution 4.0 International

La licencia de este ítem se describe como Attribution 4.0 International