Assessment of occupational exposure to extremely low frequency magnetic fields in hospital personnel

dc.contributor.authorÚbeda, Alejandrospa
dc.contributor.authorMartínez, María Antoniaspa
dc.contributor.authorCid Torres, María Antonia
dc.contributor.authorChacón, Lucíaspa
dc.contributor.authorTrillo, María Á.spa
dc.contributor.authorLeal, Jocelynespa
dc.date.accessioned2013-11-27T17:26:45Z
dc.date.available2013-11-27T17:26:45Z
dc.date.embargoEndDate2100-01-01
dc.date.issued2011spa
dc.description.abstractIt has been proposed that chronic exposure to extremely low frequency (ELF) magnetic fields (MF) in occupational environments could represent a risk factor for a number of disorders. Medical and technical workers in hospitals have been reported to be exposed to relatively strong ELF fields. The present work aims to characterize exposure to MF in the 5 Hz to 2 kHz frequency range in a large hospital through both instantaneous environmental measurements and personal monitoring of workers. The study was conducted in different working environments of a hospital with about 4400 employees, many of them working at two or more different work stations and consequently, exposed to MF levels that were expected to be unevenly distributed in space and time. The results indicate that: (1) The dominant frequency at the studied environments was 50 Hz (average 90.8 ± 6% of the total B value); (2) The best descriptive information on a worker's exposure is obtained from personal monitoring of volunteer workers; (3) The arithmetic averages of exposure levels obtained from the monitoring ranged from 0.03 ± 0.01 µT in nurses to 0.39 ± 0.13 µT in physiotherapists; and (4) The description of the MF environment through spot measurements in the workplace, although coherent with the data from personal monitoring, might not adequately estimate MF exposure in some professional categories.spa
dc.description.impact1.842 JCR (2011) Q2, 31/85 Biology; Q3, 52/74 Biophysicsspa
dc.identifier.citationÚbeda, A., Martínez, M. A., Cid-Torres, M. A., Chacón, L., Trillo, M. A., & Leal, J. (2011). Assessment of occupational exposure to extremely low frequency magnetic fields in hospital personnel. Bioelectromagnetics, 32(5), 378-387.spa
dc.identifier.doi10.1002/bem.20644spa
dc.identifier.urihttp://hdl.handle.net/11268/1014
dc.identifier.urihttps://doi.org/10.1002/bem.20644
dc.language.isoengspa
dc.peerreviewedSispa
dc.rights.accessRightsembargoed accessen
dc.subject.unescoCiencias médicasspa
dc.titleAssessment of occupational exposure to extremely low frequency magnetic fields in hospital personnelspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublication80442059-fc8b-459f-b19b-51eb23b0c4f1
relation.isAuthorOfPublication.latestForDiscovery80442059-fc8b-459f-b19b-51eb23b0c4f1

Files