Safety and Anatomical Accuracy of Dry Needling of the Quadratus Femoris Muscle: A Cadaveric Study

Loading...
Thumbnail Image
Identifiers

Publication date

Authors

Sánchez Montoya, Marta
Vallecillo, Néstor
Guerineau, Fabien

Advisors

Editors

Journal Title

Journal ISSN

Volume Title

Publisher

SDG

goal-3

Metrics

Google Scholar

Research Projects

Organizational Units

Journal Issue

Abstract

Deep dry needling (DDN) is commonly applied in physiotherapy to treat musculoskeletal pain. The quadratus femoris (QF) muscle, located in the ischiofemoral space (IFS), represents a clinically relevant yet anatomically complex target. However, limited evidence exists on the safety, accuracy, and reliability of non-ultrasound-guided DDN in this region. Aims: To assess the safety and accuracy of a standardized, non-ultrasound-guided DDN approach to the QF muscle, and to evaluate the intra- and inter-rater reliability of key procedural outcomes. Additionally, to determine the agreement between ultrasound imaging and anatomical dissection as validation methods for needle placement. Methods: An experimental cross-sectional study was conducted on five fresh cadavers (n = 24 approaches) by two physiotherapists with different DN experience. A standardized dry needling protocol was executed without ultrasound guidance, and anatomical and procedural variables were documented. Reliability (intra/inter-rater) was assessed for needle size, sciatic nerve (SN) puncture, IFS targeting, and overall success. In a subset, needle placement was validated through ultrasound and subsequent dissection. Results: The IFS was reached in 70.8% of procedures, and the SN was punctured in 16.7%. Inter-rater reliability for needle size was poor (κ = 0.04). Agreement between ultrasound and dissection was excellent for the ischiofemoral location and success (100%) and moderate for non SN puncture (90%; κ = 0.62). Conclusions: The standardized protocol demonstrated moderate accuracy and revealed a relevant clinical risk when targeting the quadratus femoris muscle. While inter-rater reliability was limited, agreement between ultrasound and dissection methods was high, supporting their complementary use for validating needle placement in anatomically complex procedures.

Description

Keywords

Bibliographic reference

Sánchez-Montoya, M., Almazán-Polo, J., Hernández, N. V., Cotteret, C., Guerineau, F., Monreal-Redondo, D. D. G., & González-de-la-Flor, Á. (2025). Safety and anatomical accuracy of dry needling of the quadratus femoris muscle: A cadaveric study. Healthcare, 13(15), 1828. https://doi.org/10.3390/healthcare13151828

Type of document

Attribution-NoDerivatives 4.0 International

La licencia de este ítem se describe como Attribution-NoDerivatives 4.0 International