Precision of stereophotogrammetry in complete arch implant recordings: A clinical study

dc.contributor.authorEstibalez Recasens, Maria
dc.contributor.authorSerrano Granger, Carlos
dc.contributor.authorSantamaría Laorden, Andrea
dc.contributor.authorAndreu Vázquez, Cristina
dc.contributor.authorOrejas Pérez, Jaime
dc.date.accessioned2025-03-09T10:28:19Z
dc.date.available2025-03-09T10:28:19Z
dc.date.issued2025-01-26
dc.description.abstractStatement of problem. Stereophotogrammetry has been proposed as an alternative to intraoral scanners for recording the location of multiple dental implants. Most studies evaluating its accuracy have been in vitro, and clinical studies are lacking. Purpose. The purpose of this clinical study was to evaluate the precision of a stereophotogrammetry system for complete arch prostheses supported by 6 implants. Material and methods. A total of 10 participants with a completely edentulous maxilla with 6 multiunit implant abutments were recruited. For each participant, 5 recordings were made using a stereophotogrammetry device (PIC system; PIC dental). From the resulting standard tessellation language (STL) files, linear and angular Euclidean distances were recorded. A statistical analysis of the measurements obtained was used to determine their repeatability and to identify maximum discrepancy values. A comparative analysis of the standard deviation values was performed with the Kruskal-Wallis and Sidak statistical tests. (α=.05). Results. For linear distances, the mean ±standard deviation precision was 14.71 ±12.2 μm, with a maximum discrepancy of 61 μm. For the angular measurements, the mean ±standard deviation precision was 0.072 ±0.064 degrees, with a maximum discrepancy of 0.345 degrees. Statistically significant differences (P<.05) were found among the different implant spans. Conclusions. The results suggested that the stereophotogrammetry device was sufficiently precise for recording implant locations in complete arch prostheses supported by 6 implant abutments.spa
dc.description.filiationUEMspa
dc.description.impact4.3 Q1 JCR 2023; 1.177 Q1 SJR 2023; No data IDR 2023spa
dc.description.impact
dc.description.impact
dc.description.sponsorshipSIN FINANCIACIÓNspa
dc.identifier.citationEstibalez-Recasens, M., Serrano-Granger, C., Santamaría-Laorden, A., Andreu-Vázquez, C., & Orejas-Pérez, J. (2025). Precision of stereophotogrammetry in complete arch implant recordings: A clinical study. The Journal of Prosthetic Dentistry, S0022-3913(25)00005-8. Advance online publication. https://doi.org/10.1016/j.prosdent.2024.12.021spa
dc.identifier.doi10.1016/j.prosdent.2024.12.021
dc.identifier.issn0022-3913
dc.identifier.urihttp://hdl.handle.net/11268/14130
dc.language.isoengspa
dc.peerreviewedSispa
dc.relation.publisherversionhttps://doi.org/10.1016/j.prosdent.2024.12.021spa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional
dc.rights.accessRightsopen accessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.otherImplantes dentalesspa
dc.subject.otherPrótesis dentalspa
dc.subject.sdgGoal 3: Ensure healthy lives and promote well-being for all at all ages
dc.subject.unescoOdontologíaspa
dc.titlePrecision of stereophotogrammetry in complete arch implant recordings: A clinical studyspa
dc.typejournal articlespa
dc.type.hasVersionVoRspa
dspace.entity.typePublication
relation.isAuthorOfPublicationcf17ee70-e00e-495c-b289-24c2386e79ff
relation.isAuthorOfPublicationa1efacd5-7be0-4c41-953a-0c0326dc64ad
relation.isAuthorOfPublication96441163-8faa-4570-a1b0-c26c2f41d397
relation.isAuthorOfPublication74d2eb56-d778-47c3-b338-76cd3d9e5f3c
relation.isAuthorOfPublication.latestForDiscoverycf17ee70-e00e-495c-b289-24c2386e79ff

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1-s2.0-S0022391325000058-main.pdf
Size:
2.5 MB
Format:
Adobe Portable Document Format
Description:
Artículo completo