Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics

Loading...
Thumbnail Image
Identifiers

Publication date

Authors

Madrid-Costa, David
García-Lázaro, Santiago
Albarrán-Diego, César
Ferrer-Blasco, Teresa

Advisors

Editors

Journal Title

Journal ISSN

Volume Title

Publisher

Metrics

Google Scholar

Research Projects

Organizational Units

Journal Issue

Abstract

The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF<SUP>®</SUP> intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF<SUP>®</SUP>). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 and 10 per cent contrast, no differences were found between groups A and B (p > 0.06 for all contrasts). Group A obtained better values than groups C, D and E for all contrasts (p = 0.031, p = 0.038, p = 0.032 at 100, 50 and 10 per cent of contrast, respectively). At the same time, group B obtained better values than groups C, D and E (p = 0.041, p = 0.042, p = 0.036 at 100, 50 and 10 per cent of contrast, respectively). Within the five groups, the worst results were always obtained for group E (p = 0.017, p = 0.021 and p = 0.025 at 100, 50 and 10 per cent of contrast, respectively). The results suggest that the aspheric aberration-correcting IOL studied provides comparable results, when it is combined with normal corneas and with corneas with simulated low myopic ablations. When negative amounts of residual spherical aberration after cataract surgery are expected to be achieved, IOLs with more positive spherical aberration should be considered.

Description

UNESCO Subjects

Keywords

Bibliographic reference

Ruiz‐Alcocer, J., Madrid‐Costa, D., García‐Lázaro, S., Albarrán‐Diego, C., & Ferrer‐Blasco, T. (2013). Visual simulation through an aspheric aberration‐correcting intraocular lens in subjects with different corneal profiles using adaptive optics. Clinical and Experimental Optometry, 96(4), 379-384.

Type of document