Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6.0 Software on Digital Casts: A Cross-Sectional Study
Loading...
Identifiers
Publication date
Authors
Adobes Martín, Milagros
Garcovich, Daniele
Aiuto, Riccardo
Bernés Martínez, Laura
Lipani, Erica
Advisors
Editors
Journal Title
Journal ISSN
Volume Title
Publisher
Metrics
Abstract
The purpose of this study was to assess the accuracy and reliability of tooth width measurements and Bolton Indices delivered by the Clin-Check Pro 6.0 software (Align Technology, San José,
CA, USA). Fifty-four plaster casts were selected and measured with a manual calliper by a trained
and calibrated observer. The data gathered were compared with those delivered by the software on
the corresponding fifty-four virtual casts. The method reliability of the software was assessed by
comparing the measurements performed by the software on 201 pairs of clin-checks corresponding
to two consecutive treatment phases. Accuracy and reliability were statistically assessed using a
mixed model. The software tends to provide larger widths compared with the manual method.
Statistically significant differences were found in 23 teeth. At a global level, the mean difference
between the methods was −0.19 mm, with a Dahlberg error of 0.24 mm and an intraclass correlation
coefficient of 0.98. The Bolton Indices delivered by the two methods had a moderate correlation
(ICC = 0.59; 0.69). The within method reliability of the software was extremely high. Tooth width
measurements delivered by the software, despite the positive bias, can be considered accurate and
clinically acceptable for all teeth except molars. The Bolton Indices made available by the software
are not accurate and clinically acceptable, especially in the case of mandibular excess.
Description
UNESCO Subjects
Keywords
Bibliographic reference
Adobes Martin, M., Lipani, E., Bernes Martinez, L., Alvarado Lorenzo, A., Aiuto, R., & Garcovich, D. (2022). Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6.0 Software on Digital Casts: A Cross-Sectional Study. International journal of environmental research and public health, 19(6), 3581. https://doi.org/10.3390/ijerph19063581