Validity and reliability of a novel iPhone app for the measurement of barbell velocity and 1RM on the bench-press exercise
| dc.contributor.author | Balsalobre Fernández, Carlos | |
| dc.contributor.author | Marchante Domingo, David | |
| dc.contributor.author | Muñoz López, Mario | |
| dc.contributor.author | Jiménez Sáiz, Sergio Lorenzo | |
| dc.date.accessioned | 2017-05-24T12:45:23Z | |
| dc.date.available | 2017-05-24T12:45:23Z | |
| dc.date.issued | 2018 | |
| dc.description.abstract | The purpose of this study was to analyse the validity and reliability of a novel iPhone app (named: PowerLift) for the measurement of mean velocity on the bench-press exercise. Additionally, the accuracy of the estimation of the 1-Repetition maximum (1RM) using the load-velocity relationship was tested. To do this, 10 powerlifters (Mean (SD): age = 26.5 ± 6.5 years; bench press 1RM · kg-1 = 1.34 ± 0.25) completed an incremental test on the bench-press exercise with 5 different loads (75-100% 1RM), while the mean velocity of the barbell was registered using a linear transducer (LT) and Powerlift. Results showed a very high correlation between the LT and the app (r = 0.94, SEE = 0.028 m · s-1) for the measurement of mean velocity. Bland-Altman plots (R2 = 0.011) and intraclass correlation coefficient (ICC = 0.965) revealed a very high agreement between both devices. A systematic bias by which the app registered slightly higher values than the LT (P < 0.05; mean difference (SD) between instruments = 0.008 ± 0.03 m · s-1). Finally, actual and estimated 1RM using the app were highly correlated (r = 0.98, mean difference (SD) = 5.5 ± 9.6 kg, P < 0.05). The app was found to be highly valid and reliable in comparison with a LT. These findings could have valuable practical applications for strength and conditioning coaches who wish to measure barbell velocity in the bench-press exercise. | spa |
| dc.description.filiation | UEM | spa |
| dc.description.impact | 2.811 JCR (2018) Q1, 20/83 Sport Sciences | spa |
| dc.description.impact | 1.227 SJR (2018) Q1, 34/289 Orthopedics and Sports Medicine, 23/209 Physical Therapy, Sports Therapy and Rehabilitation, 29/125 Sports Science | spa |
| dc.description.impact | No data IDR 2018 | spa |
| dc.description.sponsorship | Sin financiación | spa |
| dc.identifier.citation | Balsalobre-Fernández, C., Marchante, D., Muñoz-López, M., & Jiménez, S. L. (2018). Validity and reliability of a novel iPhone app for the measurement of barbell velocity and 1RM on the bench-press exercise. Journal of Sports Sciences, 36(1), 64-70. DOI: 10.1080/02640414.2017.1280610 | spa |
| dc.identifier.doi | 10.1080/02640414.2017.1280610 | |
| dc.identifier.issn | 02640414 | |
| dc.identifier.uri | http://hdl.handle.net/11268/6435 | |
| dc.language.iso | eng | spa |
| dc.peerreviewed | Si | spa |
| dc.rights.accessRights | restricted access | spa |
| dc.subject.uem | Aplicaciones para móviles | spa |
| dc.subject.uem | Biomecánica | spa |
| dc.subject.uem | Entrenamiento deportivo | spa |
| dc.subject.unesco | Telefono móvil | spa |
| dc.subject.unesco | Deporte | spa |
| dc.title | Validity and reliability of a novel iPhone app for the measurement of barbell velocity and 1RM on the bench-press exercise | spa |
| dc.type | journal article | spa |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 46f55c86-1688-47e6-87f0-d40422ea1704 | |
| relation.isAuthorOfPublication | ffc7d1e8-f040-4a94-bde8-0353fdf7a5e3 | |
| relation.isAuthorOfPublication.latestForDiscovery | 46f55c86-1688-47e6-87f0-d40422ea1704 |

