Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simulator

dc.contributor.authorMadrid-Costa, Davidspa
dc.contributor.authorRuiz Alcocer, Javier
dc.contributor.authorGarcía-Lázaro, Santiagospa
dc.contributor.authorAlbarrán-Diego, Césarspa
dc.contributor.authorMontés-Micó, Robertspa
dc.date.accessioned2013-11-27T17:26:50Z
dc.date.available2013-11-27T17:26:50Z
dc.date.issued2012spa
dc.description.abstractAIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic ablation groups (p=0.06). All these groups achieved better results than the high hyperopic ablation group (p<0.001). At 50% and 10%, the best values of VA were obtained for the virgin corneas and for the low myopic and low hyperopic ablation groups (p>0.1, for both levels of contrast). Significant differences were found between these three corneal profiles and the other two corneal profiles (p<0.002 for high myopic and p<0.001 for high hyperopic, for both levels of contrasts). CONCLUSIONS: The results suggest that the aberration-free IOL design gives an excellent visual performance for a range of corneal spherical aberrations that could correspond to patients with virgin corneas and patients in which the corneal spherical aberration has been slightly modified by a hyperopic or myopic laser ablation.spa
dc.description.impact2.725 JCR (2012) Q1, 9/58 Ophthalmologyspa
dc.identifier.citationMadrid-Costa, D., Ruiz-Alcocer, J., García-Lázaro, S., Albarrán-Diego, C., & Montés-Micó, R. (2012). Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simulator. British Journal of Ophthalmology, 96(8), 1099-1103.spa
dc.identifier.doi10.1136/bjophthalmol-2012-301475spa
dc.identifier.issn00071161spa
dc.identifier.urihttp://hdl.handle.net/11268/1085
dc.language.isoengspa
dc.peerreviewedSispa
dc.rights.accessRightsrestricted accessen
dc.subject.unescoOftalmologíaspa
dc.titleVisual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simulatorspa
dc.typejournal articlespa
dspace.entity.typePublication
relation.isAuthorOfPublication49c11cd7-8122-4e1b-a814-94ac44f3928e
relation.isAuthorOfPublication.latestForDiscovery49c11cd7-8122-4e1b-a814-94ac44f3928e

Files